Kerotest Manufacturing
–
SHANNON & PAF III OPERATORS MANUAL - REV 3
Page 55 of 60
Code
Problem
Resolution
115
The processor is not capable of
outputting the current required
to fuse this fitting.
As long as the fitting
’
s fusion requirements are within the
specified output range of the processor. This could be an
output cable error or a calibration error. Try cleaning the
Output Lead Ends. If the problem persists, the processor will
need to be returned for service.
116
The processor is not capable of
outputting the voltage required
to fuse this fitting.
117
Input voltage is out of range and
the fusion cannot start.
Verify that the input voltage and frequency displayed on the
CONNECT FITTING screen are reasonable and within the range
specified in the Specification Table
(See page 8)
. If the
parameters displayed differ significantly from the actual input,
then there is a processor problem and it must be returned for
service.
118
Frequency is out of range and
the fusion cannot start.
119
Internal processor temperature
is out of range.
Allow the processor to cool before fusing again. This error can
be seen if multiple large fittings are fused one after the other.
120
A time of 0 seconds for the
fusion was entered or
calculated.
This is more than likely a temperature measurement problem.
Verify the temperature displayed in the CONNECT FITTING
screen is reasonable and within the range specified in the
Specification Table
(See page 8)
. If the temperature displayed
differs significantly from the actual temperature then there is a
processor problem and it must be returned for service.
121
Invalid Operator ID card
scanned.
Verify the system date is correct and if so, contact the agency
that issued the Operator ID card.
122
Not an operator card.
Contact the agency that issued the Operator ID card.
123
The operator card scanned does
not contain privileges for the
functions this machine is
capable of performing.
124
Current offset is out of spec.
Processor must be returned for calibration. You cannot fuse if
this error is detected.
125
Resistor ID fusion cannot be
completed because the value
was not decoded into a valid
fusion time.
Verify the fitting and the processor support the Resistor ID
method. If so the problem is with the fitting, the output cable,
or the processor calibration. If the problem persists with
multiple fittings, The processor will have to be returned for
service.
130
The fitting was disconnected
before the specified cooling
time.
Do not disconnect the fitting before the manufacturer
’
s
recommended cooling time has expired.
131
An undefined error was received
before the fusion time was
completed.
Unit must be returned for service.