Error Codes
Code
Problem
Resolution
100
The barcode was scanned
successfully, however the
processor cannot decode the
information into valid fusion
parameters.
This is not a barcode wand error or scanning problem. Verify
that the barcode is an ISO standard 24 digit fitting barcode.
101
Ambient temperature is out of
range.
Verify the temperature displayed in the CONNECT FITTING
screen is reasonable and within the range specified in the
Specification Table
(See page 8)
. If the temperature displayed
differs significantly from the actual temperature, then there is a
processor problem and it must be returned for service.
102
Measured resistance does not
match resistance identified in
the barcode.
Check Output Lead Ends and fitting adapters for excessive wear
and/or damage. If the Output Lead Ends and fitting adapters
are in good condition, reattach the processor to the fitting and
try again. If the problem persists, there is more than likely a
calibration or output cable malfunction.
103
Shorted Coil in Fitting.
Check for a short stab or a sorted coil.
105
Can’t maintain output voltage.
Verify the Output Lead ends are clean, the power supply is sized
correctly for the fitting you are fusing, and that the power
supply is operating correctly.
108
The power supply was shut off
during the previous fusion.
This could be anything from an improperly sized generator to
someone switching the processor off during a fusion.
109
Reference voltage out of
tolerance.
Processor must be returned for calibration. You cannot fuse if
this error is detected.
110
STOP pressed during previous
fusion.
Do not press the STOP button during the fusion unless in an
emergency situation.
111
Fusion complete with no other
errors.
There were no problems with this fusion.
112
Fitting disconnected.
Current drops close to 0 during the fusion. If the problem
persists there is more than likely an output cable problem and
the processor should be returned for service.
113
The calibration date has expired.
Send the processor in for calibration.
114
There is no valid calibration date
set.
Send the processor in for calibration.