NOTE:
If Calculated Resistance is enabled and the operator receives a Warning Code 55, refer to the appropriate
section on page 42 for instructions that detail how to proceed.
See page 29 for instructions on monitoring the progress of a fusion.
Alternate Fusion Methods
Manual Barcode Entry
**The Barcode Fusion Method is always preferred and should be used whenever possible
.
Manual Barcode
Entry Fusions require additional care and attentiveness on the part of the operator to ensure that the
appropriate fusion parameters are entered. For this reason, Manual Barcode Fusions should ONLY be
performed by a fully trained operator using specifications provided by the fitting
’s
manufacturer.
The Alternate Fusion selection screen can be accessed by pressing the
UP button
and the
DOWN button
at the
same time when the processor is displaying the SCAN BARCODE screen.
The Alternate Fusion selection screen looks like the following:
SELECT METHOD
1 Manual Barcode
2 Manual
Select the desired method by using the
UP button
and the
DOWN button
. When the desired method is
highlighted, press the
START button
.
While in Manual Barcode Mode, the operator can manually input the numbers from the barcode label
attached to the fitting to be fused. The following screen will be displayed:
ENTER BARCODE DATA
000000000000
000000000000
The cursor will begin under the first digit of the barcode. Enter the data from the barcode attached to the
fitting using the keypad
(See page 40).
When the
START button
is pressed after the last character is entered,
the processor will move to the next screen.