5
EN – Installation instructions
The radiator may only be installed by a specia-
lised tradesman.
Safety instructions
Read these instructions thoroughly prior to
installation/commissioning.
After installation
pass the instructions on
to the end used
.
WARNING
Risk of injury!
Take the weight of the radiator into ac-
count (see manufacturer's data).
From 25 kg on operate with lifting equip-
ment or several persons.
►
►
Operating conditions
Follow local regulations on operating con-
ditions and water quality.
Observe the limitations on use in damp
rooms in accordance with local conditions.
Use radiator only in closed heating sy-
stems.
Store and transport radiator only in the
protective packaging.
Observe minimum clearances between ra-
diator and circumjacent objects for air cir-
culation.
Complaint
Contact the supplier.
Disposal
Packaging and any parts that are not nee-
ded should be recycled or disposed of pro-
perly. Observe local regulations.
Technical features
Operating pressure: max. 10 bar
Test pressure: 1.3 x operating pressure
Flow temperature: hot water up to 110 °C
(230 °F)
►
►
►
►
►
►
►
►
►
•
•
•
Directions for installation
Protecting radiator from damage
When installing, only remove protective
packaging at the fastening and connection
points.
Only remove protective packaging comple-
tely during final cleaning or prior to com-
missioning.
Fixing
Note the number and position of fastening
points (see Fig. A).
Install fastening material according to
separate installation instructions.
Compact radiator connection
Unscrew painted blind plugs at the desi-
gnated connection points.
For multilayered radiators and twinwire
or alternating connection: Install accom-
panying Therm X2
®
separating plugs (see
separate installation instructions).
Connect radiator with commercially availa-
ble fittings upstream.
Tightly cap open connections with vent
plugs (top) and blind plugs.
Only existing blind plugs may be used on Ker-
mi steel panel radiators.
Valve radiator connection
Valve with factory pre-set k
V
value (see
manufacturer's data).
Vent plugs (top) and blind plugs are factory
pre-assembled.
Remove painted caps on the valve moun-
tings and dispose of, as they must not be
used as seals on the radiator.
Connect radiator with commercially availa-
ble fittings upstream on the valve moun-
tings.
Special connections
See manufacturer's data.
Commissioning
Fill the radiator and vent the radiator.
Risk
of scalding!
Check radiator and connections for leaks.
►
►
►
►
►
►
►
►
►
►
►
►
►
Summary of Contents for 6907562
Page 17: ...17 EL 25 kg 10 bar 1 3 x 110 C 230 F A Therm X2 Kermi kV...
Page 18: ...18 RU 110 C 230 F RU 25 10 1 3 110 C 230 F...
Page 19: ...19 A Therm X2 Kermi kV ZH 110 C 230 F...
Page 20: ...20 ZH 25 kg 10 bar 1 3 x 110 C 230 F A Therm X2 Kermi kV...
Page 21: ...21 110 230 A Therm X2 Kermi kV AR...
Page 22: ...22 25 10 1 3 110 230 230 110 AR FA...
Page 23: ...23 25 10 1 3 230 110 A Therm X2 Kermi kV Wert FA...