B-32
BOP-1K 031912
B.122
SYSTem:COMMunication:GPIB:ADDRess
COMMAND
SYST:COMM:GPIB:ADDR
Syntax
:
Short Form: SYST:COMM:GPIB:ADDR<INT VAL> 0 to 30
Long Form: SYSTem:COMMunication:GPIB:ADDRess<INT VAL> 0 to 30
Description:
Sets selected power supply GPIB address.
NOTE: After executing this command, subse-
quent commands must be directed to the new GPIB address. Requires MEM:UPD (PAR. B.12) to save for
power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.123
SYSTem:COMMunication:GPIB:ADDRess?
QUERY
SYST:COMM:GPIB:ADDR?
Syntax
:
Short Form: SYST:COMM:GPIB:ADDR?
Long Form: SYSTem:COMMunication:GPIB:ADDRess?
Return Value: <int_value> 0 to 30
Description:
Identifies selected power supply GPIB address.
B.124
SYSTem:COMMunication
:SERial:BAUD COMMAND
SYST:COMM:SER:BAUD
Syntax
:
Short Form: SYST:COMM:SER:BAUD {19200 | 9600 | 4800 | 2400}
Long Form: SYSTem:COMMunication:SERial:BAUD {19200 | 9600 | 4800 | 2400}
Description:
Sets the unit to operate at the specified baud rate.
See PAR. 3.5.2.2 and Figure 3-16 for special
programming considerations.
B.125
SYSTem:COMMunication
:SERial:BAUD? QUERY
SYST:COMM:SER:BAUD?
Syntax
:
Short Form: SYST:COMM:SER:BAUD?
Long Form: SYSTem:COMMunication:SERial:BAUD?
Return Value: <int_value> {19200 | 9600 | 4800 | 2400}
Description:
Returns operating baud rate.
B.126 SYST
em
:COMM
unication
:SERial:ECHO COMMAND
SYST:COMM:SER:ECHO
Syntax
:
Short Form: SYST:COMM:SER:ECHO {ON | OFF} or {01 | 00}
Long Form: SYSTem:COMMunication:SERial:ECHO {ON | OFF} or {01 | 00}
Description:
Enables (ON) or disables (OFF) echo mode
(see PAR. 3.5.6.2.2). Sending ON or 01 causes all sub-
sequent characters to be echoed back. Sending OFF or 00 turns off the character echo after the next
line terminator character. The *RST command has no effect on echo status. See PAR. 3.5.2.2 and Fig-
ure 3-16 for special programming considerations.
B.127 SYSTem:COMMunication:SERial:ECHO? QUERY
SYST:COMM:SER:ECHO?
Syntax
:
Short Form: SYST:COMM:SER:ECHO?
Long Form: SYSTem:COMMunication:SERial:ECHO?
Return Value: {01 | 00}
Description:
Returns 01 when echo mode is active (ON) or 00 when disabled (OFF)
(see PAR. 3.5.6.2.2).
B.128 SYSTem:COMMunication:SERial:PACE COMMAND
SYST:COMM:SER:PACE
Syntax
:
Short Form: SYST:COMM:SER:PACE {NONE | XON}
Long Form: SYSTem:COMMunication:SERial:PACE {NONE | XON}
Description:
Enables (XON) or disables (NONE) data flow control via the serial interface
(
see PAR. 3.5.6.2.1).
See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.129 SYSTem:COMMunication:SERial:PACE? QUERY
SYST:COMM:SER:PACE?
Syntax
:
Short Form: SYST:COMM:SER:PACE?
Long Form: SYSTem:COMMunication:SERial:PACE?
Return Value: {01 | 00}
Description:
Returns 01 when data flow control via the serial interface is enabled (XON) or 00 when disabled
(NONE)
(see PAR. 3.5.6.2.1).
Summary of Contents for BOP-MG
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 031912 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 37: ...BOP HIPWR 031912 1 17 FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 53: ...BOP HIPWR 031912 2 15 FIGURE 2 4 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 54: ...2 16 BOP HIPWR 031912 FIGURE 2 5 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 64: ......
Page 132: ......
Page 192: ......