3-10
BOP HIPWR 031912
To change the background, press
#
from the power-up screen, Highlight Background, press
!
, highlight Black or White, then
$
to save. Press
$
exit and save for power-up or
%
to
apply the changes (without saving for power-up) and exit.
3.2.5.2
DISPLAYING PROGRAMMED SETTINGS IN REMOTE MODE
When Remote Debug is set to OFF (default), the programmed settings for main and protection
channels that are displayed on the LCD in local mode, are not displayed while in remote mode
and the LCD reads “Display settings off.” When set to ON, the programmed settings for main
and protection channels are displayed, however the unit responds more slowly in remote mode.
To change the Remote Debug setting, press
#
from the power-up screen (Figure 3-3), High-
light Remote Settings, press
!
, highlight On or Off, then
$
to save. Press
$
exit and save
for power-up or
%
to apply the changes (without saving for power-up) and exit.
TABLE 3-3. DISPLAY (OPERATOR CONVENIENCE) MENU FUNCTIONS
SETTING
CHOICES
(
BOLD
= Factory Default)
FUNCTION
NOTE: To save any of the functions listed below for power-up it is necessary to first change SAVE DISPLAY CHG at the password
setup (see PAR. 3.2.4.3and Figure 3-5) from DISABLE to ENABLE.
GRAPHIC DISPLAY
Meters
75s Graph
30s Graph
15s Graph
7.5s Graph
3.8s Graph
1.5s Graph
0.8s Graph
0.5s Graph
0.3s Graph
0.15s Graph
0.04s Graph
0.08s Graph
METERS - Output voltage and current are displayed on representations of ana-
log meters.
GRAPH - Displays a sample of the output for the time indicated (see Figure 3-
4). The complete time-line uses 240 points. E.g., selecting 2 Second Graph
means that 2S/240 = 50ms sampling, i.e., every 50ms a snapshot of the output
state is used to produce a single point.
DISPLAY
BACKGROUND
White
Black
WHITE - Sets the background to white and displays black characters.
BLACK - Sets the background to black and displays white characters.
REMOTE
DEBUG
Off
On
OFF - LCD does not show programmed settings for main and protection chan-
nels while in remote mode of operation (local mode is unaffected).
ON - Programmed settings for main and protection channels are displayed,
however the unit responds more slowly.
KEY PRESS BEEP
On
Error Only
Off
ON - provides an audible beep for each key press and for each error received.
ERROR ONLY - silences the beeps for each key press; errors will still cause
beep.
OFF - silences all beeps including key presses and errors except for power-up
and unit faults.
WAVEFORM STOP
Output Off
Last Level
Current Lvl
Output Off - When waveform is stopped (either count complete or
%
pressed), output freezes at whatever level the waveform was at when
%
was
pressed or count completed, then after a brief delay output is set to STANDBY
(disabled).
Last Level - When waveform is stopped (either count complete or
%
pressed), waveform runs through full cycle. The output stops at the last gener-
ated value of the waveform (e.g., for a sinewave segment of 0° to 270°, 10V
amplitude, 0V offset, when F5 is pressed the output will end up at -10V).
Current lvl - When waveform is stopped (
%
pressed), output freezes at what-
ever level the waveform was at when
%
was pressed.
NOTE: Control display contrast by pressing
#
twice to dynamically change the contrast, then press
#
to set when contrast is
acceptable. Contrast can also be set directly by pressing
#
once and using
T
and
R
as needed (see PAR. 3.2.5.1).
Summary of Contents for BOP-MG
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 031912 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 37: ...BOP HIPWR 031912 1 17 FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 53: ...BOP HIPWR 031912 2 15 FIGURE 2 4 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 54: ...2 16 BOP HIPWR 031912 FIGURE 2 5 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 64: ......
Page 132: ......
Page 192: ......