BOP HIPWR 031912
3-35
$
. Then highlight a waveform location designated
Empty
and press
$
to save or
%
to abort
the change and exit. The copied waveform may then be modified and saved with a new name if
desired (see PAR. 3.3.9.7).
3.3.10
RESET
CAUTION: PRESSING RESET WILL CAUSE VOLTAGE TRANSIENTS TO APPEAR AT
THE OUTPUT WHICH MAY DAMAGE A CONNECTED LOAD. SWITCH IS
RECESSED TO PREVENT INADVERTENT ACTIVATION.
Pressing
RESET
causes the power supply to execute a complete power on sequence to reset
the power supply to the power up settings (see PAR. 3.3.7).
3.3.11
OPERATOR TESTING
The Test System submenu is entered by pressing
%
from the power-up screen, then highlight
Revision/Test and press
!
. Upon power-up all tests are flagged as
Untested
. Table 3-13 lists
the tests that can be run. Highlight the choice and press
#
to run the selected test.
TABLE 3-13. REVISIONS/TEST MENU
SETTING
CHOICES
(
BOLD
= Factory Default)
FUNCTION
MAXIMUM OUTPUT
VOLTAGE XX
CURRENT YY
(Cannot be highlighted)
XX.0
YY.0
Displays rated output voltage and current of power supply. including all slaves
connected in parallel or series.
TEST
DISPLAY
Status (see NOTE below)
Automatic test, reports status messages (see NOTE below).
KEYPAD
Status (see NOTE below)
Requires depressing keys indicated on LCD.
This test requires pressing every key on the keypad, plus moving the
ADJUST control clockwise and counterclockwise, with the ADJUST control
depressed and released. As the keys and control function pass the tests, the
corresponding function on the LCD is highlighted. When the last test is suc-
cessful, the LCD displays “passed.” The test must be completed within two
minutes, otherwise a “Failed” indication is displayed.
INTER-
FACE
Status (see NOTE below)
Automatic test, reports status messages (see NOTE below).
SERIAL
Status (see NOTE below)
Automatic test of serial port - requires installation of loop back test connector.
(see PAR. 3.5.6.4). Reports status messages (see NOTE below).
ANALOG
Status (see NOTE below)
Automatic test which does not affect unit output. Reports status messages
(see NOTE below).
OUTPUT
Status (see NOTE below)
WARNING: DANGEROUS VOLTAGES ARE PRESENT AT THE OUTPUT
TERMINALS: DO NOT TOUCH! DISCONNECT LOAD BEFORE RUNNING
THIS TEST.
Output is automatically programmed to +
E
Onom
then –
E
Onom
,
then to 0V. Test duration is less than 2 Seconds. Reports status messages
(see NOTE below).
REVISIONS
DISPLAY
INTERFACE
ANALOG
(Cannot be highlighted)
x.xx
y.yy
z.zz
Displays current firmware revision for display, interface and analog proces-
sors.
NOTE: Test status is as follows:
UNTESTED
Initial status when first entering menu.
TESTING
Test is running.
PASSED
Test was successful.
FAILED
Test failed.
FAIL EXT
SERIAL test failed - verify loop back connector installed (see PAR. 3.5.6.4).
Summary of Contents for BOP-MG
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 031912 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 37: ...BOP HIPWR 031912 1 17 FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 53: ...BOP HIPWR 031912 2 15 FIGURE 2 4 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 54: ...2 16 BOP HIPWR 031912 FIGURE 2 5 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 64: ......
Page 132: ......
Page 192: ......