BOP-1K 031912
B-19
B.71 [SOURce:]LIST:SET:SAMPle? QUERY
LIST:SET:SAMP?
Syntax:
Short Form: LIST:SET:SAMP?
Long Form: LIST:SET:SAMPle?
Returns: <exp_value>
Description:
Returns sample pulse duration.
Returns sample pulse duration set by LIST:SET:SAMP command,
between 0.00025 and 0.034 Second.
If
sample pulse duration
has not been set, error 100- “com-
mand error” results.
B.72 [SOURce:]LIST:SET:TRIGger COMMAND
LIST:SET:TRIG
Syntax:
Short Form: LIST:SET:TRIG <time>,<transistor>
Long Form: LIST:SET:TRIGger <time>,<transistor>
<time> = 0.00025 to 0.034 (Seconds)
<transistor> = ON or OFF
Description:
Enables the output trigger and establishes pulse-width.
Used to establish EXT_C (pin 5) and
EXT_E (pin 6) of External Protection port as an output trigger instead of an output off flag. Once
LIST:SET:TRIG is sent, these pins function as an output trigger (see Table 2-4) until LIST:CLE (PAR.
B.49) is sent, restoring the function to output off flag. See Figure B-7 for example. The pulse width,
between 0.00025 to 0.034 (Seconds) is established by <time>. When <transistor> = ON, the transistor
across EXT PROTECT PORT pins 5 and 6 is on (conducting) while pulse is active. When <transistor>
= OFF, the transistor across EXT PROTECT PORT pins 5 and 6 is off while pulse is active.
B.73 [SOURce:]LIST:SET:TRIGger? QUERY
LIST:SET:TRIG?
Syntax:
Short Form: LIST:SET:TRIG?
Long Form: LIST:SET:TRIGger?
Returns <value> = trigger pulse-width between 0.00025 and 0.034 Second
Description
: Returns trigger pulse-width.
If trigger pulse duration has not been set, error 100- “command error”
results
.
B.74 [SOURce:]LIST:SET:WAIT COMMAND
LIST:SET:WAIT
Syntax:
Short Form: LIST:SET:WAIT value
Long Form: LIST:SET:WAIT value
where:
<value> = time-out for a wait command between 0.00025 and 0.034 Seconds
Description:
Establishes the time-out for a wait command.
If this command is not sent, the time out period will
be 0 indicating an infinite wait time. (See Figures B-6 and B-7.)
B.75 [SOURce:]LIST:SET:WAIT? QUERY
LIST:SET:WAIT?
Syntax:
Short Form: LIST:SET:WAIT?
Long Form: LIST:SET:WAIT?
Returns <value> = time-out for a wait command between 0.00025 and 0.033 Second
Description
:
Returns the time-out for a wait command. Returns 0 if LIST:SET:WAIT not sent, indicating infinite wait
time.
B.76 [SOURce:]LIST:TRIGger COMMAND
LIST:TRIG
Syntax:
Short Form: LIST:TRIG <value>
Long Form: LIST:TRIGger <value>
where:
<value> = programmed current (Amps) for current list, or programmed voltage (Volts) for voltage list.
Description:
Similar to LIST:VOLT or LIST:CURR, except also allows Output Off flag of External Protection
Port to be used to trigger an external device.
In addition to setting the output to the <value> speci-
fied (for duration established by LIST:SET:TRIG), causes the Output Off flag transistor (EXT_E, pin 5,
and EXT_C, pin 6, of the External Protection port) to be set to the state (on or off) for the duration set
by the LIST:SET:TRIG command.
If the trigger duration is not established by the LIST:SET:TRIG command, a -221 “Settings conflict”
error results. This command must be preceded by LIST:CURR or LIST:VOLT command, otherwise a -
221 “Settings conflict” error results. The entries on the dwell list must match the values on the current
or voltage list, otherwise a -226 “Lists Not Same Length” error results. (See Figure B-7.)
Summary of Contents for BOP-MG
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 031912 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 37: ...BOP HIPWR 031912 1 17 FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 53: ...BOP HIPWR 031912 2 15 FIGURE 2 4 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 54: ...2 16 BOP HIPWR 031912 FIGURE 2 5 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 64: ......
Page 132: ......
Page 192: ......