BOP HIPWR 031912
3-33
FIGURE 3-11. SAMPLE WAVEFORM
2. The initial waveform settings are displayed (see Table 3-11 and Table 3-12 for parameter
details. Use
!
to modify the initial settings for the waveform. For each parameter, use
$
to save the setting.
Name
CAP CHARG
Mode
VOLTAGE
Protection
Positive
10
Negative
10
Count
0
Segment
Type
Neg Ramp
Frequency (Hz)
50
Amplitude (p-p)
4
Offset
8
When all settings are complete, press
$
to save for power-up. This step creates a repeat-
ing negative ramp starting at +10V decreasing to +6V since it is a 4V p-p signal riding on an
8V offset. The frequency of 50 Hz establishes the time duration of 20 ms for the segment.
3. From the Waveform Settings screen, highlight segment NEG RAMP 50.0HZ 4.00 R and
press
@
to insert a new segment. Use
!
to modify the following settings of the new seg-
ment. For each parameter, use
$
to save the setting.
Type
Level
Period (Sec)
0.002
Offset
0
Initial/Repeat
Initial
When complete, press
$
to save for power-up. This step changes the 2ms, 0V level to be
executed only once at the beginning of the waveform.
Summary of Contents for BOP-MG
Page 2: ......
Page 10: ......
Page 20: ...x BOP 1K 031912 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 37: ...BOP HIPWR 031912 1 17 FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Page 53: ...BOP HIPWR 031912 2 15 FIGURE 2 4 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 54: ...2 16 BOP HIPWR 031912 FIGURE 2 5 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 64: ......
Page 132: ......
Page 192: ......