To specify the type of close, select a Channel Action Type from the box in the upper right before
closing a channel. The options are:
•
Channel Close
: Close the selected channel without affecting the state of any other channels.
•
Exclusive Slot Close
: Close the selected channel and open any closed channels in the same
slot.
•
Exclusive Close
: Close the selected channel and open any closed channels in the instrument
(the only closed channel is the selected channel).
You can open all channels in a slot by clicking
Open Slot
.
You can open all channels in the instrument by clicking
Open All
.
For more information on opening and closing channels, see
(on page
Configure channels from the web interface
To configure channels from the web interface, right-click the channel. The Channel Configuration
dialog box is displayed.
Figure 50: Channel configuration dialog box