Controller
106
Electrical Control
⑤
Time Button:
Normally, LCD displays the current time of the setting clock (however, LCD would display
12:00 when the first time power to the wire controller or reset the wire controller). Press this
key lasting for 4 seconds, the clock will flashing at the frequency of 0.5 Sec. by using and
to adjust the time, 1 minute to be increased/decreased for every once press the
▲
/
▼
.
Long pressing the
▲
/
▼
, it will increase/decrease 4 times/sec, 10 mins/time. Release the
key when finish the clock setting, the time will stop flashing automatically.
⑥
FAN SPEED Button:
Press this button consecutively, the fan speed will circle as follow:
(This button is unavailable when in the mode of AUTO or DRY.)
⑦
TIMER Button:
Press this button, the Timing will turn on. Set Timing ON time by
▲
and
▼
. The clock will
increase and decrease once every 10 minutes; long pressing the keys it will
increase/decrease once 10 minutes/0.2 seconds.
⑧
SWING Button:
In the unit ON status, press this key at the first time, the Swing type air supply mode to be
activated. Press this key again, the function will cancel (This function could available only
equip with the coordinated entire units system.)
⑨
CANCEL Button:
Push this button to cancel the TIMER settings.
3.2.8. Indicators and functions
①
Operation mode indication:
Press MODE to display current running mode. AUTO, COOL, DRY, HEAT and FAN can be
selected. (HEAT function is invalid for cool only type unit.)
②
Temperature display zone:
Summary of Contents for Zen On 2014
Page 1: ...Contents i Service Manual 2014 ...
Page 2: ......
Page 3: ...Contents i ...
Page 4: ......
Page 6: ......
Page 18: ...Wiring Diagrams 12 Duct Type 4 Wiring Diagrams KPD 140 HN6 KPD 176 HN6 ...
Page 24: ...Field Wiring 18 Duct Type 10 Field Wiring KPD 140 HN6 KPD 176 HN6 ...
Page 41: ...Service Space Ceiling Floor Type 35 3 Service Space ...
Page 42: ...Wiring Diagrams 36 Ceiling Floor Type 4 Wiring Diagrams KPC 140 HN6 KPC 176 HN6 ...
Page 45: ...Field Wiring Ceiling Floor Type 39 9 Field Wiring KPC 140 HN6 KPC 176 HN6 ...
Page 50: ...Wiring Diagrams 44 Outdoor Units 4 Wiring Diagrams KUE 140 HTN6 KUE 176 HTN6 ...
Page 95: ...Troubleshooting Electrical Control 89 f Indoor fan speed has been out of control Eb ...
Page 98: ...Troubleshooting 92 Electrical Control c Up down panel is not closed ...
Page 103: ...Controller Electrical Control 97 3 Controller 3 1 KI 01 Wireless Remote Controller Optional ...
Page 115: ......
Page 116: ......