background image

 

INSTALLATION, OPERATION AND MAINTENANCE MANUAL 

 

K7 purification and disinfection units 

 

Please read the instructions carefully before installation. 
Give this manual to the end user.

 

 

SECURITY ADVISE SYMBOLS 

WELDOM10010-R1(03/03/21) 

 

Attention, Danger, Safety Warning!

 

 

High voltage or electric current hazard!

 

 

Danger of injury!

 

 

¡Attention! Do not stand under the load: 
Heavy weight. 

 

Attention! Wear protective glasses 
UV-A: Ultraviolet radiation. 

 

Important information. 

Summary of Contents for K7 600 A OH+FC

Page 1: ... before installation Give this manual to the end user SECURITY ADVISE SYMBOLS WELDOM10010 R1 03 03 21 Attention Danger Safety Warning High voltage or electric current hazard Danger of injury Attention Do not stand under the load Heavy weight Attention Wear protective glasses UV A Ultraviolet radiation Important information ...

Page 2: ...ures 7 Special controls 8 Remote control features 8 WIRING DIAGRAMS 8 DATASHEET 12 Exterior cleaning 14 Internal cleaning 14 REPAIRS AND REEMPLACEMENTS 15 Replacement of the consumable 15 Standard purifier motor or turbine replacement 16 Fuse replacement 17 PCB replacement 18 FAILURES AND SOLUTIONS 19 ACCESSORIES 20 DECLARATION OF CONFORMITY 21 Purifier identification 22 GUARANTEE 22 ...

Page 3: ...3 CONNECTION DIAGRAM ...

Page 4: ...4 ...

Page 5: ...nel observing these instructions and in accordance with the applicable standards In case a special control is supplied a specific manual is attached that must be used for its operation and installation Depending on the model it is not necessary to remove the service grill to connect the equipment All the connections power and control and necessary fixings are external in the standard case located ...

Page 6: ...er In this case it is necessary to open the intake grille see section repairs and replacements The RJ11 cable must be routed to the outside through a hole in the top of the housing K7 600 A OH FC SS IP55 standard control using the 7 meter RJ45 cable connect the power board located in the waterproof box above the purifier and the control located inside an IP65 waterproof box To enter the cable in e...

Page 7: ...act lenses when present and can be done easily Continue with the wash In case of skin irritation Consult a doctor Immediately call a POSISON CENTER or doctor Remove contaminated clothing Store in a well ventilated place Keep the recipient hermetically sealed Keep locked up Dispose of contents container to an approved waste disposal facility Control board features The relay boards adjust the two fa...

Page 8: ...It has its own manual where all its functions are explained Remote control features WIRING DIAGRAMS The following diagrams are attached K7 600 A Purifier and disinfectant K7 600 A OH FC with standard control Diagram WELDOE07050 Purifier and disinfectant K7 600 A OH FC CL with advanced Clever control Diagram WELDOE07055 K7 600 A SS Purifier and disinfectant K7 600 A OH FC with standard control Diag...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 DATASHEET ...

Page 13: ...13 ...

Page 14: ...a should be performed Cleaning the body of the purifier should be done with a damp cloth and a conventional detergent Do not use caustic or acid containing detergents The intake grille prevents objects from entering the internal elements It is advisable to periodically check that the intake grille is free of any object that could prevent the entry of air papers etc Internal cleaning In models with...

Page 15: ... intake grille follow these steps Remove the screws from the intake grille Gently pull the grill down Replacement of the consumable Before changing the consumable notify and indicate that is working stop the purifier with the control and make sure that the turbine has completely stopped Disassemble the intake grille as indicated in the previous step and proceed to unscrew the bottle from the react...

Page 16: ...med Standard purifier motor or turbine replacement Before changing the motor warn and indicate that is working disconnect the power supply make sure that there is no voltage and that the turbine has stopped Remove the side from the motor side Disconnect the motor connector on the power board Then loosen the turbine fixing screw Allen 2 5mm through the discharge port ...

Page 17: ...ected in the IP55 waterproof box located above the purifier Fuse replacement Before doing any manipulations warn and indicate that you are working disconnect the power supply make sure that there is no voltage and that the fans have stopped For K7 600 A OH FC and K7 600 A OH FC CL open the intake grille and remove the fuse by hand or the help of a screwdriver and replace it In the case of the K7 6...

Page 18: ... pull it K7 600 A OH FC CL advanced Clever control Open the inspection door and disconnect the cables from the board that are visible and the capacitor Unscrew the power board from the top and perform the necessary repair K7 600 A OH FC SS standard control IP55 Open the waterproof box above the purifier and disconnect all cables from the board Unscrew the bracket clamp to the waterproof box and fi...

Page 19: ...rst page More common failures and solutions Effect Problems Solutions All lights of the controller are OFF Is the RJ45 RJ11 cable the original not manipulated with no enlargements either shortenings Change cable or reconnect it correctly Does the current reaches the connection box Correctly connect the terminals of the connection box Between L and N there must be 230V Is the controller connected t...

Page 20: ...matic manual working door delay timer save energy program multi equipment management BMS Modbus connection etc It permits to take the temperatura from a place different to the control Allows the connection to a centralized management system BMS PLC etc Supports vibration dampers etc depending on the model 20m and 50m RJ45 cable ...

Page 21: ...21 DECLARATION OF CONFORMITY ...

Page 22: ...e that eventually suffer failures attributable to production defects Installation costs are borne by the buyer Products that in our opinion have been used improperly handled incorrectly improperly installed connected to voltages other than the nominal modified or repaired by unauthorized personnel or that have suffered damage during transport are excluded from any guarantee To validate the guarant...

Reviews: