Controller
100
Electrical Control
3.1.4
OPERATION INSTRUCTIONS
Install and replace batteries
Install 2 pieces of 7# alkaline batteries.
Slide the cover to install batteries and make sure to place them in right pole.
AUTO operation
Switch on the power and running indicator light on indoor unit flashes.
1. Press MODE to select AUTO.
2. Adjust temp via
▲
and
▼
. Generally the range is 17ºC ~30ºC .
3. Press ON/OFF and running indicator light on indoor unit is lightened. Air conditioner will work on AUTO mode and fan speed
is AUTO which is nonadjustable.
4. ECO is effective on AUTO operation.
COOL/HEAT/FAN operation
1. Press MODE to select COOL, HEAT or FAN.
2. Adjust temp via
▲
and
▼
. Generally the range is 17ºC ~30ºC .
3. Press FAN SPEED to select AUTO, LOW, MED or HIGH.
4. Press ON/OFF and running indicator light on indoor unit is lightened. Air conditioner will work on the set mode. Stop
operation via ON/OFF.
NOTE: On FAN mode, temp is nonadjustable and ECO is ineffective. Procedure 2 is omitted.
DRY operation
1. Press MODE to select DRY.
2. Adjust temp via
▲
and
▼
. Generally the range is 17 ~30ºC .
3. Press ON/OFF and running indicator light on indoor unit is lightened. Air conditioner will work on DRY mode. Turn off the
unit via ON/OFF.
4. On DRY mode, ECO and FAN SPEED are unavailable.
Timer operation
TIMER ON and TIMER OFF are used to turn on and turn off the unit at the set time respectively.
TIME ON operation
1. Press TIMER ON, icon SET, HOUR and ON are lightened.
2. Press TIMER ON again and adjust the time.
3. Keep pressing this button, the time will increase by 0.5 hour. When the set time exceeds 10 hours, pressing the button will
increase the time by 1 hour.
4. 0.5s after setting, remote controller will send TIME ON command to the unit.
TIME OFF operation
1. Press TIME OFF, icon SET, HOUR and OFF are lightened.
2. Press TIME OFF again and adjust the time.
3. Keep pressing this button, the time will increase by 0.5 hour. When the set time exceeds 10 hours, pressing the
button will increase the time by 1 hour.
4. 0.5s after setting, remote controller will send TIME OFF command to the unit.
Set TIME ON and TIME OFF simultaneously
1. Set TIME ON according to procedures 1 and 2 specified in.
TIME ON operation
2. Set TIME OFF as the procedures 1 and 2 specified in
TIME OFF operation
3. If both the set time of TIME ON and TIME OFF not exceed 10 hours, time OFF operation will activated 0.5 hour later than
time ON operation. If both the set time of TIME ON and TIME OFF exceed 10 hours, time OFF operation will be activated 1
hour later than time ON operation.
4. 0.5s after setting, remote controller will send TIME ON command to the unit.
Modification of timer operation
Press corresponding button and readjust the time of time ON and time OFF. Adjust the time figure to 0.00 to cancel the timer
operation.
NOTE: The time set in timer operation is the relative figure based on the clock on remote controller. Adjusting clock
is unavailable when TIME ON or TIME OFF is activated.
Summary of Contents for Zen On 2014
Page 1: ...Contents i Service Manual 2014 ...
Page 2: ......
Page 3: ...Contents i ...
Page 4: ......
Page 6: ......
Page 18: ...Wiring Diagrams 12 Duct Type 4 Wiring Diagrams KPD 140 HN6 KPD 176 HN6 ...
Page 24: ...Field Wiring 18 Duct Type 10 Field Wiring KPD 140 HN6 KPD 176 HN6 ...
Page 41: ...Service Space Ceiling Floor Type 35 3 Service Space ...
Page 42: ...Wiring Diagrams 36 Ceiling Floor Type 4 Wiring Diagrams KPC 140 HN6 KPC 176 HN6 ...
Page 45: ...Field Wiring Ceiling Floor Type 39 9 Field Wiring KPC 140 HN6 KPC 176 HN6 ...
Page 50: ...Wiring Diagrams 44 Outdoor Units 4 Wiring Diagrams KUE 140 HTN6 KUE 176 HTN6 ...
Page 95: ...Troubleshooting Electrical Control 89 f Indoor fan speed has been out of control Eb ...
Page 98: ...Troubleshooting 92 Electrical Control c Up down panel is not closed ...
Page 103: ...Controller Electrical Control 97 3 Controller 3 1 KI 01 Wireless Remote Controller Optional ...
Page 115: ......
Page 116: ......