![Kaufman & Robinson eHC 15015A Manual Download Page 14](http://html.mh-extra.com/html/kaufman-and-robinson/ehc-15015a/ehc-15015a_manual_657992014.webp)
INSTALLATION 3-3
_______________________________________________________________________
Copyright © 2010 by Kaufman & Robinson, Inc., 1306 Blue Spruce Drive, Unit A, Fort Collins, CO 80524
Tel: 970-495-0187, Fax: 970-484-9350, Internet: www.ionsources.com
3.4 Connections Between Controller Components
The connections between Controller components are shown in Fig. 3-2, which
shows the rear panels of the Auto Controller, and the Keeper, Emission and
Discharge power supplies. The individual connections required are given be-
low:
• If the 6 meter (20 ft.) input power supply cables were not connected to the
individual power supplies when they were installed in the cabinet, connect
them now. Use plugs that will match the input power sources. Again, do not
connect to Input Power before the installation is complete.
• Attach the 4 pin (female) plug connector of the 6 meter (20 feet) operating
cable to the connector on the electrical feedthrough. The connections for
the other end of this cable are described below.
• Insert the end of the operating cable BLUE wire into one of the (+) positive
connectors located on the rear panel of the Discharge Power Supply and
tighten the screw above the appropriate connector.
• Insert the end of the operating cable BLACK wire into one of the (-) negative
connectors located on the rear panel of the Discharge Power Supply and
tighten the screw above the appropriate connector.
• Insert the end of the operating cable RED wire into one of the (-) negative
connectors located on the rear panel of the Keeper Power Supply and tight-
en the screw above the appropriate connector.
• Insert the end of the operating cable ORANGE wire into one of the (+) Posi-
tive connectors located on the rear panel of the Keeper Power Supply and
tighten the screw above the appropriate connector.
• Insert one end of the short RED wire into one of the (-) negative connectors
located on the rear panel of the Keeper Power Supply and tighten the screw
above the appropriate connector.
• Insert the other end of the short RED wire into one of the (-) negative connec-
tors located on the rear panel of the Emission Power Supply and tighten the
screw above the appropriate connector.
• Insert one end of the short BLACK wire into one of the (+) positive connec-
tors located on the rear panel of the Emission Power Supply and tighten the
screw above the appropriate connector.