53 from 56
20.1.3
Obstruction in the swing path
The motorised antenna has reached the mechanical
stop or is jammed! If the unit encounters an obstruc
-
tion, the CAP reverses 10°. This allows the obstruc-
tion to be removed more easily.
Check whether the turntable is obstructed (e.g. by a
branch).
20.1.4
Overtemperature of the rotation motor
The turntable motor temperature is in the critical
range. Allow the turntable to stand for a few minutes
in its current position until the turntable motor temper-
ature has reduced.
20.2
Further messages
There is a connection problem between the receiver
and the polar antenna. See the table below.
Possible cause
Remedy
The receiver and polar antenna are not connected
with the Master cable (marked in red) but with the
Slave cable.
Connect the receiver and the polar antenna with
the Master cable (marked red)
1)
.
The ignition is switched on.
Switch off the ignition.
There is a voltage at the core (green) marked with
"IGNITION".
Check the "IGNITION" core and correct the wiring
as required
1)
.
None of the above reasons.
Reset the turntable
2)
.
Contact our Service section
3)
.
1)
see 5.6.6, p.23 and 5.6.9, p.25.
2)
see 15.3, p.46.
3)
see 7.2, p.27.