59
LCD Brightness:
Set brightness of the hardwired display(s) from
10
—
100%
System Units:
Change from US Standard units to Metric
Factory Reset:
Resets any changed parameters a user has made back to the factory defaults for that
configuration.
CAUTION! Never disable a Fault Alarm without being certain that the issue is with a bad sensor.
Disabling a fault and running the system can cause serious damage or injury.
High Pressure Fault:
Disables the
‘
High Pressure
’
shutdown fault in the event of a feed pressure sensor failure.
System Stall Fault:
Disables the
‘
System Stalled
’
shutdown fault in the event of a failed rotoflow sensor. System
stalled alarms occur when the control board does not sense any product water being produced, and shuts down
to protect the pump from running dry.
Poor Quality Fault:
Disables the
‘
High Salinity
’
shut down fault in the event that the salinity probe has failed or
cannot be calibrated within range.
NOTE: The diversion valve will always be active when this fault is disabled.
ALWAYS VERIFY PRODUCT QUALITY BEFORE DRINKING. Serious health risks may occur.
Prefilter Fault:
Disables the
‘
Service Prefilter
’
shut down fault in the event that the boost pressure sensor has
failed or cannot be calibrate within range.
CAUTION: Permanent damage to the feed pump can occur if this
fault is disabled, use caution when operating this system with this fault disabled.
User Settings
Spectra Connect Settings, Cont
’
d
Fault Alarms
Summary of Contents for Spectra Catalina 340C
Page 2: ...2...
Page 15: ...15 John Guest Super Speedfit Fittings...
Page 50: ...50 This page intentionally left blank...
Page 64: ...64 Wiring Schematic...
Page 73: ...73 Parts 1...
Page 74: ...74 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Page 78: ...78...
Page 80: ...80...
Page 83: ...83...