background image

Operating manual

DI resin filter

®

PHOTOVOLTAIC CLEANING SYSTEM BY CLEANTECS

Summary of Contents for SOLA-TECS 0200272

Page 1: ...Operating manual DI resin filter PHOTOVOLTAIC CLEANING SYSTEM BY CLEANTECS ...

Page 2: ...t liability for the functionality of the device When it is handled in other than the usual manner When it is used for applications not specified in the manual inappropriate use When the safety instructions are not adhered to The processing filter can be damaged by Operating and installation errors Incorrectly opening the bottle Swapping over connections and hoses except by Cleantecs Independent st...

Page 3: ... an optimum water quality for cleaning glass surfaces Any other use especially the processing of water for manufacturing foodstuffs e g beverages is regarded as inappropriate use and is prohibited The regulations of DIN1988 EN1717 apply to the installation 1 4 Operating temperatures pressures and connections The system must be protected from frost The temperature in the operating room must be at l...

Page 4: ...ax C 30 Water temperature min C 2 Pure water quality ppm 10 3 Overall view Scope of delivery 1 Water inlet with stopcock 2 Water outlet with stopcock 3 Pressure tank resin cartridge 4 TDS measuring unit for inlet and outlet water 5 Sturdy transportation case 6 Microfilter for pre filtering 7 Microfilter for post filtering 8 Water meter 9 Quick release tank latch 1 2 3 4 5 6 7 8 9 3 ...

Page 5: ...thout filter has been checked and therefore shows a meter reading 0 4 3 Complaints If the packaging is damaged have this verified by the supplying party Store the packaging and transport carton in a safe place in case the unit needs to be returned Complaints relating to transport damage that has not been verified by the shipping company cannot be accepted The specialist dealer must be immediately ...

Page 6: ...e ballcock 2 and connect the hose of the high pressure cleaner to the water outlet 2 then open the pure water outlet 2 again 3 Remove the hoses and close all ballcocks for transport so that water cannot flow out of the unit Open the ballcocks to drain the water and depressurise the unit before transport 5 3 Integrated TDS measuring unit Sturdy measuring device designed for industrial applications ...

Page 7: ...er supply authority responsible specification of the overall hardness b By measuring the mineral content using the TDS meter 4 6 1 Maintenance and replacement of the bottles 1 Close the supply water stopcock 1 2 Depressurise the system Do this by opening the water outlet stopcock 2 3 Remove the cartridge from the carriage by releasing the hose clips and hose connections 9 4 Replacement of the resi...

Reviews: