manualshive.com logo in svg
background image

 

 

Item No: 25980 

BA DW 010-02 Sauna Plus 8 Basic EN.docx 

Language:: EN 

Operating Instructions   

 

 

Automatic sauna splash system 

Type Sauna Plus 8 Basic 

 

 

 

 

Содержание Sauna Plus 8 Basic

Страница 1: ...Item No 25980 BA DW 010 02 Sauna Plus 8 Basic EN docx Language EN Operating Instructions Automatic sauna splash system Type Sauna Plus 8 Basic ...

Страница 2: ...eparator system separator 11 3 2 8 Connection set option 11 3 3 Identification of the device identification plate 11 3 4 Technical data 12 3 5 Transport storage 12 4 Installation 13 4 1 Select the installation site 13 4 2 Installation instructions assembly suggestion 13 4 3 Mechanical installation 14 4 4 Hydraulic installation 15 4 5 Electrical installation 16 5 Commissioning 17 5 1 Commissioning ...

Страница 3: ...intenance protocol 34 9 6 Spare parts list wear parts list list of consumables 35 10 Appendices 36 Imprint All rights reserved Copyright by WDT Werner Dosiertechnik GmbH Co KG Edition see footer Reproduction of any kind and translation into other languages even in excerpts is only permitted with the express authorisation of the company WDT Werner Dosiertechnik GmbH Co KG These operating instructio...

Страница 4: ...ection work may only be carried out by appropriately trained specialists 1 3 Symbols used This document uses the following types of safety notices as well as general notices DANGER DANGER denotes a safety notice which if disregarded may lead to death or serious personal injury CAUTION CAUTION denotes a safety notice which if disregarded may lead to minor or mod erate personal injury ESD SENSITIVE ...

Страница 5: ...or chemical wear and tear For these we assume a warranty of 1 2 year Our merchandise management programme requires an invoice for each delivery including warranty ser vices When returning a defective component upon review you will receive a corresponding credit if applicable We request a return within 14 days The costs for subsequent damage and for the processing of warranty claims are excluded Th...

Страница 6: ...Handling of chemicals risks to humans and the environment Important information concerning the handling of chemicals and fragrances can be found in the safety data sheets provided by the fragrance manufacturers With the automatic sauna splash system a fragrance is added to the water and dosed on the sauna heater The fragrance concentration in the water is so low that there is no danger for people ...

Страница 7: ...the oven shower head must be laid in such a way that the line can drain itself at a decline without water trap without non return valve If the splash line cannot drain e g installed at an incline or water trap in the line a system separation unit in accordance with DIN EN 1717 for non toxic liquids without free outlet must be installed in the inlet of the automatic sauna splash system In ad dition...

Страница 8: ... system for non draining splash line Item no 24321 8 Hose connection Ms nickel plated 3 8 IG for PTFE hose 6x1 mm Item no 19282 3 2 Product description The automatic sauna splash system Sauna Plus 8 Basic is a dosing system for a fully automated splash on the sauna heater During the splash a fragrance is automatically dosed into the splash water The pause time the quantity of water splash quantity...

Страница 9: ...tons 2 Control housing 3 Safety combination in accordance with DIN EN 1717 non return valve aera tor 4 Solenoid valve 5 Pressure switch 6 Pipe bracket 7 Fragrance dosing valve 8 Dirt filter 9 Shut off ball valve 10 Peristaltic pump 11 Mounting plate 12 Power socket for push button 13 Fragrance pressure line 14 Fragrance suction line 15 Warning notices 16 Fragrance container 17 Console for fragranc...

Страница 10: ...n when the splash line is draining so that no water can be sucked back into the water supply Furthermore the piping consists of a shut off solenoid valve 4 the splash pipe with integrated washer a pressure switch 5 for pressure monitoring and the dosing valve 3 2 4 Oven shower head series The standard scope of delivery includes a oven shower head consisting of a stainless steel pipe d 18x200 mm wi...

Страница 11: ...ption The sauna splash connection set for connecting the automatic sauna splash system to the wall bushing The connection set is available with various hose lengths 5 m Item no 20101 1 10 m Item no 20101 15 m Item no 20101 2 20 m Item no 20101 3 3 3 Identification of the device identification plate Enter the data from your device s identification plate here Field 1 Enter serial number Field 2 Ente...

Страница 12: ...chnical room max 70 Ventilation in and out Recommended in the technical room Software version V 2 1 Hardware version NT 35 R HMI 3 5 Transport storage Please check the device immediately upon receipt for potential transport damage ATTENTION The device may be damaged by frost or high temperatures Avoid exposure to frost during transport and storage Do not store systems and devices next to objects w...

Страница 13: ...storage space be well aerated and ventilated 5 A waste water connection must be available Only necessary for version with system separation 4 2 Installation instructions assembly suggestion The automatic sauna splash system is installed on a wall in the technical room The line to the sauna heater should be as short as possible Pay attention to the space required for operation and maintenance of th...

Страница 14: ... wall with 4 screws and ensure easy accessibility Install wall bushing for oven shower head option Tip For the installation and secure fastening of the oven shower head a wall bushing with two 3 8 AG thread connections made of stainless steel is available see Chapter 3 2 5 Drill a hole of approx 18 mm in the sauna wall approx 10 15 cm above the heater then insert the wall bracket with the rosette ...

Страница 15: ...ash line 3 8 interior thread to the wall bushing option 3 8 AG Screw the oven shower head hand tight onto the wall bushing Only use Teflon tape for sealing to keep the shower head cleaning as simple as possible For variant b The line cannot drain DANGER If the splash line cannot drain e g installed at an incline or water trap in the line an additional system separation unit in accordance with DIN ...

Страница 16: ...ainst being reactivated Connect the earth connection Pos 18 to the on site earthing cable Open close the housing Unlock the locking knob with a screwdriver Press down on both recessed grips until the housing snaps open Ro tate the cover to the side To close the housing follow the procedure in reverse sequence ATTENTION Connect the automatic sauna splash system to the sauna control unit so that the...

Страница 17: ...Unscrew the cover of the fragrance delivery container and drill a hole with a diameter of 7 mm in the cover Screw the cover back on and place the delivery container on the console of the auto matic sauna splash system 3 Secure the fragrance container with the Velcro tape CAUTION The console is designed for loads up to 5 kg If this load is exceeded place the fragrance containers on a separate shelf...

Страница 18: ...er carrier For dismantling the roller carrier and the hose bracket please proceed in the reverse sequence Plug the safety plug in a corresponding power socket and turn on the device at the main switch If the switch on delay is activated the first splash can be delayed between 0 120 minutes after switching on the voltage This prevents the splash from being made on the cold sauna heater After that t...

Страница 19: ...arts when the display shows the start display If the sub menus are displayed the splash cycle is blocked Use the 3 operating buttons to navigate in the menu The control unit s main menu is simply structured and easy to operate It consists of an operating level with the following menu items 1 Pause time with cyclic operation locking time with but ton operation 2 Water quantity 3 Fragrance quantity ...

Страница 20: ...tage circuit switiching off Solenoid valve splash Schema Sauna Plus 8 Basic button mode menu Delivery status button illumination on SL 6 1 3 Button illumination 100 Button illumination dimmed Frangrance pump Figure 20 Flow chart cyclic operation In the Cyclic operation operation mode an additional splash can be called up via a connected push button After a push button prompt the pause time starts ...

Страница 21: ...t is closed Normal operation If the white square is shown in the display the operating contact is open Standby mode no splash Push button contact The push button symbol appears in the display when the Button operation operation mode is set If the black dot is shown in the display a signal is pending at the button input or at the input of the 230 V control unit A splash occurs If the white dot is s...

Страница 22: ...rted Set the desired locking time between the splashes No further splash is possible during the time period set here 6 3 3 Water quantity Set the duration of the water splash onto the sauna heater opening time of the so lenoid valve 6 3 4 Fragrance quantity Set the run time of the fragrance dosing pump during the splash The run time of the fragrance quantity is limited to the set run time of the w...

Страница 23: ...splash cycle is run In turn the solenoid valve and the pressure switch are queried and the pump is activated If no fault indication is displayed the splash test was successful Otherwise one of the described fault indications appears 6 3 10 Contrast Adjust the contrast for the display 6 3 11 Language Select the desired language 6 3 12 Info Here you can find information about the device type and sof...

Страница 24: ...ly and secured against being reactivated 7 1 1 Check change hose kit The pump hose in the pump is subject to mechanical and chemical stresses Therefore the pump hose must be checked every time the fragrance is changed in order to detect damage in due time and to replace the dosing hose The dosing hose must be replaced at least every 6 months and more frequently in the case of aggressive fragrances...

Страница 25: ...mp and track the air bubble with the fragrance pump running If the air bubble in the suction pressure hose is transported further the fra grance dosing is functioning correctly If the air bubble only moves back and forth the dosing valve is blocked To clean the valve loosen the dosing hose from the dosing valve unscrew the dosing valve and wash it out with warm water or rinse it with methylated sp...

Страница 26: ...ter 24 h of fault free opera tion Water supply interrupted Water pressure too low Check water supply Check supply pressure Fault indication 2 Pressure switch fault Prior to opening the solenoid valve the contact of the pressure switch is closed further splash blocked Pressure switch defective Splash line blocked Short circuit cable plug Manipulation Check renew pressure switch Check clean renew li...

Страница 27: ...ly shown in the display the auto matic splash system is blocked By resetting the fault indication 3 the user is automatically forwarded to the Pressure switch test menu see Chapter 6 3 8 Button illumination without function Fuse defective Renew fuse No splash Fuse defective Solenoid valve defective no water supply pressure Device input filter blocked Splash line blocked Check fuses Check renew sol...

Страница 28: ...to the corresponding information on the packaging When in doubt information may be obtained from the institution responsible for disposal at your location If this is not possible dispose of as hazardous waste 8 2 Decommissioning When decommissioning the automatic sauna splash system switch off the device at the main switch For decommissioning of more than 30 days the fragrance container must be re...

Страница 29: ...Automatic sauna splash system type Sauna Plus 8 Basic Index 02 Date modified 22 02 2022 OI No BA DW 010 02 Sauna Plus 8 Basic EN docx Page 29 of 36 9 Documents 9 1 Declaration of conformity ...

Страница 30: ...dex 02 Date modified 22 02 2022 OI No BA DW 010 02 Sauna Plus 8 Basic EN docx Page 30 of 36 9 2 Wiring Diagram Notice for wiring diagrams The wiring diagrams can also be found near the device s control cabinet Wiring diagram cyclic operation button operation ...

Страница 31: ...02 Sauna Plus 8 Basic EN docx Page 31 of 36 9 3 Commissioning protocol instruction This protocol is to be completed by the commissioning technician Without a completed and signed commissioning protocol all warranty claims become void The commissioning protocol is located in the accompanying documentation ...

Страница 32: ...clic operation Button opera tion Switch on delay 30 minutes 0 120 minutes 1 Pump test Sequence pro gramme MV test Sequence pro gramme Pressure test Sequence pro gramme Splash test Sequence pro gramme Contrast 10 0 15 1 Operation data sheet Menu Factory setting Setting ranges Step during commissioning Optimised during oper ation Date Date Pause time for cyclic op eration Locking time for button ope...

Страница 33: ...h on delay 30 minutes 0 120 minutes 1 Pump test Sequence pro gramme MV test Sequence pro gramme Pressure test Sequence pro gramme Splash test Sequence pro gramme Contrast 10 0 15 1 Operation data sheet Menu Factory setting Setting ranges Step during commissioning Optimised during oper ation Date Date Pause time for cyclic op eration Locking time for button operation 15 minutes 1 90 minutes 1 Water...

Страница 34: ...2 Date modified 22 02 2022 OI No BA DW 010 02 Sauna Plus 8 Basic EN docx Page 34 of 36 9 5 Maintenance protocol Carry out the specified maintenance tasks in order to protect any warranty claims The maintenance protocol is located in the accompanying documentation ...

Страница 35: ...Sa 12709 38 Gear motor Sa 24 VDC 13557 39 Mounting screws set 17067 Water supply part 09 Ball valve Ms 18895 08 Inclined angle filter Ms 11479 03 Pipe aerator 1 2 with RV 19877 04 Solenoid valve VA NC 230 VAC 29152 Solenoid valve plug with LED and cable 13082 14 Suction hose PE 4x1 1 m 12064 05 Pressure switch 11335 1 Protective cap for pressure switch Ms 11337 Dosing pipe 16865 Dosing valve angle...

Страница 36: ... sauna splash system type Sauna Plus 8 Basic Index 02 Date modified 22 02 2022 OI No BA DW 010 02 Sauna Plus 8 Basic EN docx Page 36 of 36 10 Appendices Commissioning protocol Maintenance protocol Personal notes ...

Страница 37: ...s Optional system separation unit not required No Optional system separation unit required and installed No Optional system separation unit required but not installed no operation permitted according to DIN EN 1717 1 6 Fragrance container connected 1 7 All test programmes checked 1 8 Settings made and operation mode selected 1 9 Flow pressure of supply water line checked Attention Other consumers ...

Страница 38: ......

Страница 39: ...1 Month 12 Comment additional work 1 Sauna Plus 8 and Sauna Plus 8 Basic 1 1 Check hose pump s for function and leak tightness 1 1 2 Check the device for leak tightness 3 1 3 Perform test programmes 3 1 4 Operate fittings check for function and leak tightness 3 1 5 Exchange hose set only use WDT original part 6 1 6 Clean the device 6 1 7 Check and clean dosing valve s 6 1 8 Clean the heater shower...

Страница 40: ......

Отзывы: