23
Commissioning
New System Start
-
Up and Testing
Use this procedure when starting a new watermaker for the first time and
whenever the
system contains preservative or cleaning chemicals.
Avoid running the system if the vessel is in contaminated water, such as a dirty harbor or
canal. The system should be fully run tested before leaving on an extended journey. It is
preferable to sacrifice a pre
-
filter by testing the system briefly in turbid water rather than
waiting to get offshore to discover a problem or deficiency in the installation. If the location or
weather prevents proper testing refer to the section Dry Testing with an Artificial Ocean.
1.
First Check That:
•
Seacock is open
•
Toggle switch on the Feed Pump
Module is in the Run Auto position
•
Domestic fresh water pressure system
is on.
2.
Open pressure relief valve 1/2 turn and remove the
Green Tag and washer!
3.
Turn on the power to the system and the Spectra Connect screen will display,
“
Has the
system been stored with chemicals?
”
Press
‘
Yes
’,
to start the Purge sequence. Note: The
watermaker will shut down if the pressure relief valve is left closed during the Purge mode.
•
Alarm will sound
•
Display will read
“
Has the
system been stored with
chemicals?
”
•
Confirm the Pressure Relief
Valve is open
•
Press
‘
Yes
’
to start the Purge
sequence
Warning! Damage may occur if the purge sequence is bypassed and
the membrane is pressurized with storage chemical in it.
Summary of Contents for Spectra Catalina 340C
Page 2: ...2...
Page 15: ...15 John Guest Super Speedfit Fittings...
Page 50: ...50 This page intentionally left blank...
Page 64: ...64 Wiring Schematic...
Page 73: ...73 Parts 1...
Page 74: ...74 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Page 78: ...78...
Page 80: ...80...
Page 83: ...83...