51
In the event of a sensor failure
resulting in a shut down due to a false alarm, the failed sensor can
be overridden using the programming function on the display (page 74). High Pressure, Service
Prefilter, System Stalled (airlock), and Salinity Probe Failed can all be overridden and the system
will still run automatically with all other functions intact.
Be absolutely certain that the alarm is
false before overriding the automatic controls.
In the event of complete Connect control failure
, the system may be operated manually as
follows:
•
Switch on the feed pump by turning the toggle switch to RUN MAN. The automatic safety
controls are disabled in manual mode. Shut the unit down if the Clark pump does not cycle, if
air is continuously present in the intake line, or if the feed pump is excessively noisy.
•
Always discard the product water for the first few minutes of operation as the initial product
water may not be potable. Take a water sample by loosening the 1/4
-
inch product tube fitting
at either the feed pump module or the membrane outlet. Check it with a handheld salinity
meter or taste it.
•
The diversion valve is an electrically operated three
-
way valve, which is normally energized by
the Connect controls in order to send water to the tank. It will not open automatically in
manual mode, and must be opened using the mechanical override button.
The button is
located on the side closest to the Clark pump cylinder
. Push the manual override button in
and rotate 1/4 turn clockwise to open the valve.
Alarm Override and Manual Operation
Diversion valve
manual override
button
Summary of Contents for Spectra Catalina 340C
Page 2: ...2...
Page 15: ...15 John Guest Super Speedfit Fittings...
Page 50: ...50 This page intentionally left blank...
Page 64: ...64 Wiring Schematic...
Page 73: ...73 Parts 1...
Page 74: ...74 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Page 78: ...78...
Page 80: ...80...
Page 83: ...83...