Components
Feed Pump Module
Mount the feed pump module on a vertical surface, up to 3
-
feet (1.0M) above the waterline. It is preferable to mount as
low as possible. Locate in an area that allows easy access to
both the filters, and the left hand side of the enclosure. Keep
future maintenance in mind when choosing a location, and do
not mount above water
-
sensitive equipment. The feed pump
has overheat protection and will not operate properly at
ambient temperatures over 113°F (48°C).
Sea Strainer and Boost Pump Module:
Mount close to the
intake through
-
hull, below the waterline, in a location that
can handle water spillage during service. The boost pump
power cable will connect to the feed pump module.
Fresh Water Flush Module:
The fresh water flush module
may be located in any convenient location near the feed
pump module. It should be mounted with the filter housing
vertical and accessible, with
2”
below the housing for filter
changes. Do not install over electrical equipment. The unit
contains the charcoal filter, a solenoid shut off valve, and a
flush water flow regulator.
IF INSTALLING THE Z±ION, SEE Z±ION INSTALLATION
INSTRUCTIONS FOR MORE DETAILS.