7
If the equipment is to be shut down, and
there is not danger of frost,
disconnect the water input,
disconnect the power supply.
By the option of the base exchanger.
Disconnect the water input between the
base exchanger and the cooler.
Rinse the equipment ( with base ex-
changer (optional)) with anti freeze
agent.
Rinse the base exchanger with a con-
centrat salt agent.
Empty all swimming cointainers, discon-
nect the pipes, and drain offf the water.
Empty the high pessure pump, discon-
nect the pipes from the high pressure
pump, and drain the water.
Disconnect the high pressure pipe at the
head of the pump, and drain the water.
Store the cleaning agent container and
the fuel container at a non-freezen
place.
If not surtain when shutting down, please
call your local service.
1 Water connection (by customer)
2 Pipe disconnector (optional)
3 salt tank (optional)
4 base exchanger (optional)
5 Control head (optional)
6 condensing electro motor
7 swimming valve
8 Swimming container anti freeze
9 proportioning device water softener flu-
id (RM 110, optional)
10 Swimmer tank for cold water
11 Temperature limiter, temperature regulator
12 Warm water tank
13 Solenoid valve for cold water
14 Solenoid valve for warm water
15 filter anti freeze pump
16 Centrifugal pump
17 Strainer
18 Reactor *)
19 High pressure pump
20 Manometer *)
21 Overflow valve *)
22 Back up valve
23 Cleaning agent valve
24 Dosing pump
25 Cleaning agent filter
26 Cleaning agent container
27 Trigger gun
*) in the cylinder head of the high pressure
pump.
When cleaning the water flows through a
–
water connection,
–
base exchanger (optional)
–
condensing electro motor
–
High pressure pump
–
flow-type heater,
–
to the hand blowing gun.
If there is danger of frost, the water is flows
through the following cycle:
–
Swimming container anti freeze
–
Centrifugal pump
–
high pressure hose
–
Hand blowing gun
–
Swimming container anti freeze
Has the softening capacity of the base ex-
changer reached 80%, than the night
folling, a regeneration process will be pre-
formed.
If the lever of the hand blowing gun is let
loose during the operation, then the cycle
valve will open, and the high pressure
pump will stay in operation. When opening
the blowing gun gain, the high pressure jet
does function.
If the power supply is interrupted because
of a short circuit or overload.
IThe motor power supply is interrupted be-
cause of overheating.
Adjusts the warm ater temperature accord-
ing to the setting.
The heater will switch off when tempera-
tures exceed 90°C and must be unlocked
manually afterwards.
Turns on the anti freeze cycle by danger of
frost (unter 3 °C) .
Shutdown
Shutting down by danger of frost
Function
Flow pattern
Discription concerning the
function
Monitoring and safety devices
Hardness sensor in the base exchang-
er (optional)
Overflow valve *)
Circuit breaker
Winding head thermostat
Attemperator
Temperature controller
Anti freeze thermostat
28