English
5.906-736.0 Rev. 00 (07/15)
147
View with opened maintenance flap on the right
1 Screw
2 Support
3 Thermostat switch emission temperature
Unscrew the maintenance flap on the right.
Upon changing the temperature sensor: disconnect it at
the thermostat switch.
Upon replacement with thermostat switch:
Open screws, remove the holder and unscrew the ther-
mostat switch from the holder.
Disconnect the cable connection.
NOTE
Observe the cable run with the electrical connection!
View from below
1 Temperature sensor warm water
2 High-pressure line from the booster heater to the high-
pressure connection
3 High-pressure line from the safety block to the boiler
View from below
1 Bracket
2 Temperature sensor warm water
Open support (clips) of the HP pipeline.
Carefully clean the temperature sensor.
NOTE
When changing the temperature sensor, this must be dis-
connected electrically directly at the control.
11.12.6 Cleaning / changing the temperature sensor warm water
Summary of Contents for HDS 9/50 De Tr1
Page 46: ...46 English 5 906 736 0 Rev 00 07 15 1 Reflector on both sides 2 Marker light on both sides...
Page 182: ...182 English 5 906 736 0 Rev 00 07 15 13 3 Troubleshooting Yanmar diesel engine...
Page 184: ...184 English 5 906 736 0 Rev 00 07 15...
Page 185: ...English 5 906 736 0 Rev 00 07 15 185 14 3 Maintenance plan Yanmar diesel engine...
Page 189: ...English 5 906 736 0 Rev 00 07 15 189 HDS 13 20 and 17 20 safety block...
Page 190: ...190 English 5 906 736 0 Rev 00 07 15 HDS 9 50 and 13 35 pump head...
Page 198: ...198 English 5 906 736 0 Rev 00 07 15...
Page 199: ...English 5 906 736 0 Rev 00 07 15 199...
Page 200: ...200 English 5 906 736 0 Rev 00 07 15...
Page 201: ...English 5 906 736 0 Rev 00 07 15 201...
Page 202: ...202 English 5 906 736 0 Rev 00 07 15...
Page 203: ...English 5 906 736 0 Rev 00 07 15 203...
Page 204: ...204 English 5 906 736 0 Rev 00 07 15...