Deutsch
5.962-786.0 Rev. 05 (06/13)
43
Note
The text is shown in English.
A Unlocking button
B LCD display
C Bar graph (approx. 20% of the nominal pressure
per field)
D Fault message pumps 1-4
E Change value (-) or move cursor to the left
F Change value (+) or move cursor to the right
G Acknowledgment button (OK)
H Cancel (ESC)
I System pressure
J Collective fault
K Water shortage
L The respective pump is switched on.
–
When the system is ready to operate, the current
operating hours of the high pressure pumps are
shown alternating with the operating pressure.
–
When errors are triggered, these are shown on the
display as well (see "Help with errors").
Danger
Risk of injury on account of the emanating water jet
that could be hot!
Danger
Check the high pressure hose for damage before
every use. Please arrange for the immediate replace-
ment of a damaged high pressure hose.
Check high pressure hose, pipe connections, fit-
tings and water jet for damage every time before
use.
Check hose coupling to ensure that it sits firmly
and is leak-proof.
Turn the main switch to position “0”.
Shut off water supply.
Activate hand spray gun until device is pressure-
less.
Open the water supply.
Turn the main switch to position “1”.
Press the unlocking key.
Perform the cleaning operation.
Note
If the cleaning break exceeds the set delay time (min.
30 seconds), the appliance will stop. At the same
time, a adjustable operation readiness period will be
started. Within this operation readiness period, the
appliance will automatically switch on because of the
drop in pressure when the hand spray gun is opened.
Press the unlocking key.
Turn the main switch to position “0”.
Shut off water supply.
Activate hand spray gun until device is pressure-
less.
Secure the hand spray gun using the safety catch
so that it doesn't open accidentally.
If the appliance is not to be used for a longer period
or if it is not possible to install it in a frost-free environ-
ment, you must take the following measures (see
chapter "Maintenance and care", section "Anti-freeze
protection"):
Drain water.
Flush device with anti-freeze agent.
Switch off the main switch and secure it.
5.5.3
Display
A
B C D
E F G H I J K L
5.5.4
Making the plant ready for operations
5.5.5
Switch-off in case of emergency
5.5.6
Turning on the Appliance
5.5.7
Getting the system ready for operations
5.5.8
Turn off the appliance
5.6
Shutdown