Deutsch
5.962-786.0 Rev. 05 (06/13)
25
included in the scope of delivery
possible accessories
- Accessories not available
*temperature sensor PT 100 (6.375-485.0) is set to 68°C in the software.
Optional accessories
VA frame
o
o
o
o
o
o
Steel panels
o
o
o
o
o
o
VA panels
o
o
o
o
o
o
Floor structure
o
o
o
o
o
o
HDC 40/8
HDC40/8H HDC 60/8
HDC60/8H HDC 80/8
HDC80/8H
Performance data
Working pressure
MPa
(bar)
16 (160)
16 (160)
16 (160)
16 (160)
16 (160)
16 (160)
Max. excess oper-
ating pressure
(safety valve)
MPa
(bar)
20 (200)
20 (200)
20 (200)
20 (200)
20 (200)
20 (200)
Flow rate
l/h (l/min) 4000
(66,6)
4000
(66,6)
6000 (100) 6000 (100) 8000
(133,3)
8000
(133,3)
Water connection
Min. feed volume
l/h (l/min) 4000
(66,6)
4000
(66,6)
6000 (100) 6000 (100) 8000
(133,3)
8000
(133,3)
Feed pressure
(min.)
MPa
(bar)
0,15 (1,5)
0,15 (1,5)
0,15 (1,5)
0,15 (1,5)
0,15 (1,5)
0,15 (1,5)
Max. feed pres-
sure
MPa
(bar)
0,6 (6)
0,6 (6)
0,6 (6)
0,6 (6)
0,6 (6)
0,6 (6)
Max. feed temper-
ature
°C
60*
85
60*
85
60*
85
Electrical connection
Current type
--
3~
3~
3~
3~
3~
3~
Frequency
Hz
50
50
50
50
50
50
Voltage
V
400
400
400
400
400
400
Connected load
kW
23
24
34
35
45
46
Electrical protec-
tion (slow)
A
50
50
80
80
100
100
Maximum allowed
net impedance
Ohm
0.180+j0.1
13
0.180+j0.1
13
0.158+j0.0
99
0.158+j0.0
99
0.138+j0.0
87
0.138+j0.0
87
Power supply
mm
2
4x 16
4x 16
4x 35
4x 35
4x 35
4x 35
Dimensions and weights
Length
mm
1168
1168
1168
1168
1168
1168
Width
mm
768/800
768/800
768/800
768/800
768/800
768/800
Height
mm
1424
1424
1881
1881
1881
1881
Weight incl. panel kg
360
380
485
505
560
580
Noise emission