manualshive.com logo in svg
background image

1

Part # 8533-066-001 5/11

WCAD-Series Vended Washers 

Machine Programmng Instructions

Содержание WCAD Series

Страница 1: ...1 Part 8533 066 001 5 11 WCAD Series Vended Washers Machine Programmng Instructions ...

Страница 2: ...decrease and the Warm temperature button to increase The value will change in 1 steps The range of values is from 00 00 to 99 99 When the desired right coin value is displayed push Start button once to store the new value and a second time to move to the next Coin Price programming step To exit the Coin Price programming mode push the Cold temperature button for 5 seconds 2 Left Coin The display w...

Страница 3: ... programmed to charge a fee for this or the feature can be turned off The default setting is off 0 00 The display will blink first a PC P indicating Plus Cycle price and then price back and forth To change the value use the Hot temperature button to decrease and the Warm temperature button to increase The value will change in 1 steps The range of values is from 00 01 to 99 99 When the desired pric...

Страница 4: ...l return to the bath selection When the desired cycle time is selected push Start Bath Water Temperature The display shows the letter t in the left digit and the letters CC appear in the right two digits This is the bath water temperature The selection choices are shown below but for the coin washer the value is defaulted to CC As it is not selectable with a coin washer the owner pushes Start to c...

Страница 5: ... wash bath the default is over ridden for that cycle by the customer when the temperature is selected Bath Water Level L LO low The owner can change the displayed value but for a coinwasher only LO will be put into the cycle Bath Delay Fill dF The selections are d for delay the bath time until water level is reached or t for decrement bath time during the fill Bath Spin Time S 0 to 10 minutes for ...

Страница 6: ...isplay will show an Ad advance in the display The washer will advance to the next bath segment The water will drain before the advance will occur To exit the Rapid Advance mode push and hold the Cold temperature button for 5 seconds or more NOTES Step 1 When the Rapid Advance mode is used the cycle time will no longer be correct Step 2 By skipping steps with rapid advance the door may not open imm...