BR/BD 100/250 R BP / RI
Basic settings and service procedures
Page 83 / 171
Service Manual 08.2007
5.1.5 Access to the test mode
(with program switch S9, position 5)
Requirements
- Unit switched off
- Program switch (S9) in Pos 5 (polish)
- Key switch (SO) in „O“ position
Main relay (K1)
switches off
yes
no
Display
shutdown soon
Switch off key switch (SO)
Display
Battery:
E....F
Water/C:
E....F
Error display
?
Display
Error display
>10s
yes
no
Display
Set TEST
MODE?
Main relay (K1)
is connected
Self-test
o.k.?
Display
BR 100/250R
Self-test
- Hold i-button inch function
and
- Switch on key switch (SO)
no
Call up service/
operator menu
See 5.1.5.3
Adjust brush pattern
On-Off function or o-
pen/closed See 5.1.2.1
Drive pedal calibration
See 5.1.5.1
LED test
See 5.1.5.2
Call up service/
operator menu
Move BK AB
I_brush
0A
Move BK AUF
I_brush
0A
Fan (on/off) 0
0mA
Magnet brake
open/closed
Calibrate accelerator
pedal?
lluminated symbol test
Note:
- If the rotary pulse generator is turned in an anti-clockwise direction the cursor acts in the opposite direction, i.e. the menu is
called up from the last to the first parameter. The last saved cursor can be called up again after quitting the menu, e.g. by
switching back to the standard display (battery display).
- Switch off the key switch (S0) to quit test mode
yes