BR/BD 100/250 R BP / RI
Troubleshooting
Page 139 / 171
Service Manual 08.2007
6.2.3 Lifting module (A4) and Cleaning module (A3) error messages
Module
Fault
classification
Display code
Action
H
Cable break
Lifting motor -
suction beam
(M30)
H1/142
Equipment version:
BR/BD 100/250 R
1. Disconnect lifting motor (M30) at A4/X4-2, 6.
2. Perform key switch (S0) reset.
3. If fault remains, replace module A4.
4. Check lifting motor (M30) for low impedance:
–
Check terminal EXT-X1 in distribution box (rear
axle).
–
Check motor supply cable for crimped, kinked
and worn areas.
–
Check Molex plug connections.
–
Check motor carbon.
Cable break
Lifting motor -
pre-sweeping
system/side
brush
(M50/M40)
H2/142
Equipment version:
BR/BD 100/250 RI with pre-sweeping system
1. Disconnect lifting motor (M50) at A4/2/X4-2, 6.
2. Perform key switch (S0) reset.
3. If fault remains, replace module A4/2.
4. Check lifting motor (M50) for low impedance:
–
Check motor supply cable for crimped, kinked
and worn areas.
–
Check Molex plug connections.
–
Check motor carbon.
Equipment version:
BR/BD 100/250 RI with side brush
1. Disconnect lifting motor (M40) at A4/1/X4-2, 6.
2. Perform key switch (S0) reset.
3. If fault remains, replace module A4/1.
4. Check lifting motor (M40) for low impedance:
–
Check motor supply cable for crimped, kinked
and worn areas.
–
Check Molex plug connections.
–
Check motor carbon.
Cabling error
switch inputs
A4/X4-1, 5, 8
Hy/152
Refer to Hy/151, however, for A4/X4-1, 5, 8
(S30, S31).
Power electronic
unit for lifting
module (A4) is
too hot
Controls are
too hot!
Cool off!
1. Switch off key switch (S0).
2
.
Let control unit cool for at least 5 minutes.
3. Switch on key switch (S0).
4. If the error remains, replace A4 clone in question.