Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 100 / 171
Service Manual 08.2007
5.3 Setup menu
5.3.5 Module parameter manufacture settings
PARAMETER-SETUP, sequence and factory settings BR 100/250R(I) - State 2005/05/20
Module
Parameter presentation in
display
Factory setting
min:step:max
Notes
Language
selection: 0
0=German 1=Engl
0
0.1
Language for Display texts, for the time being only
German and English aviable.
Setup valid for:
Head CPU version:
from 1.2
Drive module version:
up to 1.2
Clean module version:
from 1.2
Lift module version:
up to 1.0
Accessory module version:
up to 1.0
Version of this parameter list:
2
Last amendment made on:
20.05.2005
Parameter setup distributed to documentation/service on:
21.05.2005
Order
Service
access
Development
access
1
X
Machine model:
BR 100/250 R
BR 100/250 R
BR 100/250 R
BD 100/250 R
BR 100/250 RI
BD 100/250 RI
Selection of model for correct details in
information menu of the display.
2
X
Beacon light when
reversing 0
0
0.1
If activated automatically switches on beacon light
for reversing.
3
X
Standby time:
30 min
30 min
10min:10min:240min
Time after which an inactive machine switches
itself off (only key-operated switch on)
4
X
Discharge voltage
32.4 v= 1.80 V/Z
1.80 V/Z
1.65:0.01:1.95 V/Z
Voltage at which cleaning stops. Can only by
driven and possibly lighting switched on.
5
X
Reset voltage
37.8 v= 2.10 V/Z
2.10 V/Z
2.10:0.01:2.20 V/Z
Minimum voltage after battery charge in order to
beable to clean.
6
X
Minimum brush
pressure:
40A
40A
20A:10A:50A
Start point for brush current contriller at minimum
brush pressure setting (1 bar in the display)
7
X
Lift mot. Brush 1
0=ES; 1=Block
1
0.1
Option 1: Lift motor for brush works without limit
(end position) switch.
8
X
Filter vibration
time pre.sweeping:
15 s
15s
5s:5s:120s
Duration of filter cleaning.
9
X
Display only
for RI
versions
Filter pause time
pre-sweeping:
120 s
120s
15s:15s:600s
Fan running time between consecutive filter
cleaning operations
10
X
Display only
for RI
versions
Sweeper after run
time after stop:
3 s
3s
0s:1s:5s +)
Time during which the sweeper still runs when
the machine at a standstill before the main brush,
side brush and fan switch off and the brush head is
raised.
11
X
Display only
for RI
versions
Sweeper fan after
run time from
stop: 5 s
5s
0s:1s:20s +)
Length of time during which sweeper suction fan
still runs when machine at a standstill before it
switches off
12
X
Display only
for RI
versions
Warning messages?
0=yes; 1=no: 0
0
0.1
Option 1: Warning messages are generally hidden
in the display.
13
X
Chemical metering
On=1; Off=0: 0
0
0.1
Option 1: Activates the hose pump control for
cleaning agent metering.
14
X
B hrs:
0h00m
Load Backup?: 0
0
0.1
Option 1: Reload the backed up operating hours
from the cleaning module in the head CPU.
15
X
Max speed
forwards: 6.0 km/h
6 km/h**)
2.0km/h:0.5km/h:
9km/h
Maximum forwards travel speed during transport
1
X
Max speed
backwards: 3.5 km/h
3.5 km/h**)
2.0km/h:0.5km/h:
9km/h
Maximum reverse speed (this also replaces the
working speed).
2
X
Approach ramp: 2
2
1:1:5
Acceleration rate of the drive motor at full throttle.
3
X
#)
Braking ramp: 2
2
1:1:5
Braking rate of the drive motor when accelerator
raised.
4
X
##)
Max. motor current:
125A
125A in basic unit
180A in basic unit
with pre-sweeper
20A:5A:180A
Maximum current to which the drive motor is
limited in motor mode during blockage.
5
X
Max. braking
current:
125A
125A in basic unit
180A in basic unit
with pre-sweeper
20A:5A:180A
Maximum current to which the drive motor is
limited during braking.
6
X
Overload limit:
70A
70A in basic unit
120A in basic unit
with pre-sweeper
10A:5A:120A
If the current exceeds this value a time counter is
activated. if the current falls back under this limit
the time counter is switched off again.
7
X
Gas potentiometer
type:
1
1
0.1
Specifies whether accelerator pedal used with or
without micro switch.
8
X
Gas potentiometer
supply
8.0V
8.0V
3.0V:0.1V:15.0V
Accelerator pedal supply voltage.
9
X
Motor constant:
0.045 m/(Vs)
0.045m/(Vs)**)
0.01:0.005:
0.255 m/(Vs)
Speed constant of the drive motor for calibration of
the speed controller.
10
X
System parameter
(head CPU)
Clean module (1)
Clone 1: control
of the scrubbing
brush and
vacuuming
Available in:
Basic unit
Basic unit + side
brush
Basic unit + pre-
sweeper
CANNOT BE ADJUSTED!
Driving module