Lock Set-up for KT-1-PCB
Warning
: Controlled door locks may be governed by regulatory bodies and always
be installed according to local regulations. In most instances, there are strict lim-
itations to installing fail-secure devices and fail-safe locking devices such as mag-
netic locks or other similar locking devices on doors used as emergency exits.
Hooking Up Inputs
Connect devices to inputs 1 to 4. Resistors for all inputs are 5.6K ohm (if selected).
The KT-1 has an on-board capability of monitoring 4 input points. Each onboard
input is supervised with or without end-of-line resistors (5.6K ohm). The maximum
distance of one line is 600 m (2,000 ft) with AWG #22 in a single or double EOL con-
figuration.
Note:
Onboard Inputs can be defined with: none, single or double EOL (End-of-
Line) resistor(s) according to your EntraPass software settings. For UL listed install-
ations use of supervised EOL resistors is required.
Inputs 1-2 are automatically reserved for the controlled door. The door contact is
assigned to input 1 and the associated request-to-exit detector as input 2. There is
no obligation to follow these rules but this standard convention facilitates servicing.
© Copyright, 2016, all rights reserved
31
Summary of Contents for KT-1
Page 1: ......
Page 6: ...6 Copyright 2016 all rights reserved ...
Page 10: ...10 Copyright 2016 all rights reserved ...
Page 17: ...Wiring Charts KT 1 Inputs and Outputs View Copyright 2016 allrights reserved 17 ...
Page 18: ...KT 1 PCB Inputs and Outputs View Copyright 2016 all rights reserved 18 ...
Page 19: ...KT 1 EU Inputs and Outputs View Copyright 2016 allrights reserved 19 ...
Page 20: ...KT 1 PCB EU Inputs and Outputs View Copyright 2016 all rights reserved 20 ...
Page 32: ...Inputs for KT 1 Inputs for KT 1 PCB Copyright 2016 all rights reserved 32 ...
Page 50: ......