background image

KT-1 EU Inputs and Outputs View

© Copyright, 2016, all rights reserved

19

Summary of Contents for KT-1

Page 1: ......

Page 2: ...tion Notes 7 Technical Support 9 Overview of Features 11 Wiring Charts 17 System Architecture 21 LED Patterns 23 Installation Connection Power 27 Reset Configuration 38 KT 1 Models Expansion Kits Related Items 46 Compliance Specifications 47 Copyright 2016 all rights reserved ...

Page 3: ...ous arrangement or contract If You do not agree to the terms of this EULA KANTECH is unwilling to license the SOFTWARE PRODUCT to You and You have no right to use it SOFTWARE PRODUCT LICENSE a The SOFTWARE PRODUCT is protected by copyright laws and internationalcopyright treaties as well as other intellectualproperty laws and treaties The SOFTWARE PRODUCT is licensed not sold 1 GRANT OF LICENSE Th...

Page 4: ...transfer must also include allprior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights KANTECH may terminate this EULA if You failto comply with the terms and conditions of this EULA In such event You must destroy allcopies of the SOFTWARE PRODUCT and allof its component parts g Trademarks This EULA does not grant You any rights in connection with any trademarks o...

Page 5: ... WHETHER EXPRESSED OR IMPLIED INCLUDING ALLIMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALLOTHER OBLIGATIONS OR LIABILITIES ON THE PART OF KANTECH KANTECH MAKES NO OTHER WARRANTIES KANTECH NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS WARRANTY NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCE...

Page 6: ...6 Copyright 2016 all rights reserved ...

Page 7: ...ich that person may be exposed in performing a task and of measures to minimize the risks to that per son or other persons The equipment is installed in a metallic cabinet that meets the applicable requirements for a FIRE ENCLOSURE Note When installed on the North American Market powered via the UL cUL Listed 40VA Transformer the KT 1 shall be connected to the mains by a LICENSED ELECTRICIAN in ac...

Page 8: ... between SELV Safety Extra Low Voltage cir cuits and NON POWER Limited Circuits Battery wires Route the battery wires away from the rest of the SELV circuits 7 It is the end user and or installer s responsibility to ensure that the disposal of the used batteries is made according to the waste recovery and recycling reg ulations applicable to the intended market 8 There are no serviceable parts wit...

Page 9: ...int com Latin America GMT 03 00 Argentina Direct 541147118711 Fax 541147118201 9 00to 18 00 ingenieria tycoint com Asia GMT 08 00 Asia Pacific Direct 31475352722 8 30to 18 00 apac support tycoint com Europe Toll Free 800 CALL TYCO 800 2255 8926 GMT 01 00 Bahrain 80004127 8 00to 18 00 emea accesscontrol support tycoint com France 330472791483 Greece 0080031229453 Russia 81080020521031 Spain 9001019...

Page 10: ...10 Copyright 2016 all rights reserved ...

Page 11: ...est standards of access control and point monitoring applications The KT 1 is available in two configurations KT 1 single gang mount KT 1 PCB More information is available near the end of this guide on expansion kits and related items KT 1 KT 1 PCB Copyright 2016 allrights reserved ...

Page 12: ...b Configuration Page can be used to verify and configure the IP settings of the KT 1 Refer to the System Architecture section of this guide for further details KT Finder The KT Finder is a stand alone application that can be used to verify and configure the IP settings of the KT 1 Refer to the System Architecture section of this guide for further details One Door Two Readers Entry Exit The KT 1 is...

Page 13: ... 1 is compatible with all the controllers The KT 1 asynchronously polls the controllers KT 100 KT 300 KT 400 and communicates with the EntraPass Gateway only when necessary This significantly reduces the amount of bandwidth required to operate your security system on the network Note The KT 100 is not UL listed model do not use in UL listed applications PoE will provide power for the unit up to 13...

Page 14: ...with the Gateway which prevents any hacking from the internet and ensures secure communications when used over the internet on a wide area network WAN 128 bit AES encryption has been validated by NIST Certificate No 3092 Inputs There are 4 onboard inputs that can be used for the following Door contact T Rex Request to Exit Detector Interlock External Alarm System Status Armed Disarmed External Ala...

Page 15: ...ng function can also be per formed by any onboard relay configured for this functionality Note Supervision is only provided to detect short circuit fault not open circuit fault Relay Outputs The KT 1 has 2 open collector onboard switch to ground relay outputs The KT 1 PCB has 2 form C relays Reader Outputs There are 4 different possible open collector switch to ground outputs Reader out puts are u...

Page 16: ...etects the site communication speed set by EntraPass as well as the communication port which can be IP ETHERNET or RS 485 COM1 Downloadable Firmware The firmware program can be downloaded from any EntraPass workstation to the KT 1 It is stored in the controller s flash memory and is upgraded without having to change any parts Trouble and Reporting The KT 1 continuously monitors its power and repor...

Page 17: ...Wiring Charts KT 1 Inputs and Outputs View Copyright 2016 allrights reserved 17 ...

Page 18: ...KT 1 PCB Inputs and Outputs View Copyright 2016 all rights reserved 18 ...

Page 19: ...KT 1 EU Inputs and Outputs View Copyright 2016 allrights reserved 19 ...

Page 20: ...KT 1 PCB EU Inputs and Outputs View Copyright 2016 all rights reserved 20 ...

Page 21: ... Global Edi tion Gateway Over the internet Over RS 485 with a USB 485 or VC 485 Application with EntraPass Global Edition and a KT NCC Over the Internet on premises Over RS 485 with a USB 485 or VC 485 Layout examples of the configurations Over the Internet with EntraPass Special and Corporate Editions with Multi site Gateway Note KT 1 can be connected to EntraPass using either RS 485 bus shown or...

Page 22: ...USB 485 with EntraPass Special Corporate and Global Editions Over the Internet with a KT NCC and EntraPass Global Edition Copyright 2016 all rights reserved 22 ...

Page 23: ...d TX1 The yellow RS 485 serial port LEDs transmit TX1 and receive RX1 activity between the KT 1and the gateway RX2 and TX2 Future use R1 Relay 1 and R2 Relay 2 Each output has a red LED indicator which turns on each time the corresponding relay is activated L1 Lock 1 and L2 Lock 2 Each lock output has a red indicator which turns on each time the corresponding output is activated POWER The green DC...

Page 24: ...E TO RETINA MAY OCCUR LED Patterns Table Mode Color Led Flashing Pattern Booting Up Blue Steady Corporate Multi site Gateway Blue 3 short pulses GlobalGateway Blue 1 short pulse Rebooting Blue 10pulses sec 50 duty cycle Card Read or Swipe Blue Single 0 5sec burst resume previous flash During Enrollment White 1 long pulse every 2 sec Enrollment Acknowledge Pink 2 5sec Burst Firmware Update Green 5 ...

Page 25: ...es 305g Cabinet Weight KT 1 PCB 13 93 ounces 395g Reader types Wiegand proximity ABA Clock and Data bar code magnetic integrated keypad smartcard and others Reader power output 12 VDC 500 mA max protected and supervised 룈 Monitored points zone inputs 4 monitored points Z1 to Z4 NO NC without EOL DRY single EOL double EOL and 1 fixed function tamper input Points maximum wiring AWG 22 600 m 2 000 ft...

Page 26: ...s Listing USA UL294 UL1076 FCC Part 15 Class B Canada ICES 003 B NMB 003 B Europe EN60950 1 EN50130 4 2011 EN61000 6 3 CE Compliance in accordance with applicable LVD and EMC Directives Australia New Zealand RCM Com pliance AES Encryption AES NIST Validation of certificate No 3092 Note The KT 1 has been tested by UL with the PoE PoE modles Phihong POE36U 1AT R and or the POE125U 4 HP R These devic...

Page 27: ... cm 13 in clear space in front of the unit The location should be easily accessible for servicing the equipment and it is recommended that con trollers be located close to the controlled doors Controllers must be located at a minimum distance of 2 m 6 ft from any high voltage equipment or wiring electrical equipment susceptible of generating elec trical interference at a minimum distance of 1 m 3 ...

Page 28: ...h mounts on the wall plate 2 Install the wall plate A to the wall using the two Phillips screws provided 3 Clip board B on the wall plate A 4 Mount the main boards C into board B 5 Mount the cover D and secure with one of the Phillips screws provided Copyright 2016 all rights reserved 28 ...

Page 29: ... the cabinet if previously removed at beginning of install ation Earth Grounding The KT 1 uses high performance communication Proper grounding must be provided to ensure proper operation Connect the ground wire to the green quick connect terminal Make an earth ground connection to the cabinet of the KT 1 con troller as per the requirements of your local electrical code Wire the E GND ter minal on ...

Page 30: ...h as electromechanical strikes and can be configured to operate fail safe or fail secure normal or reverse action Note If required the KT 1 can provide galvanically isolated output s by pro gramming any of the relays KT 1 PCB only Note Use 1 K ohm EOL End of Line resistor between and LK terminals if not used To connect the door locking device 1 Connect the negative wire from the door strike to the...

Page 31: ...ng 4 input points Each onboard input is supervised with or without end of line resistors 5 6K ohm The maximum distance of one line is 600 m 2 000 ft with AWG 22 in a single or double EOL con figuration Note Onboard Inputs can be defined with none single or double EOL End of Line resistor s according to your EntraPass software settings For UL listed install ations use of supervised EOL resistors is...

Page 32: ...Inputs for KT 1 Inputs for KT 1 PCB Copyright 2016 all rights reserved 32 ...

Page 33: ...ible access operation feedback at the controlled door One controller can be installed to control the entry of a single door or two readers can be installed on a single door and used to control both the entry and exit Out puts OUT1 and OUT2 are extra multipurpose outputs Relay Controlled Outputs The KT 1 provides two relay outputs RELAY1 and RELAY2 These outputs are open collector rated for up to 1...

Page 34: ...ntrolled Outputs for the KT 1 Relay Controlled Outputs for KT 1 PCB Auxiliary Outputs Connect auxiliary outputs to readers and local warning devices Auxiliary outputs are used for visual and audible signals They can be activated according to input con Copyright 2016 all rights reserved 34 ...

Page 35: ...ernet Category 3 double twisted pair unshielded network cable or better The RS 485 loop can operate from 1200 to 115200 Bauds under normal conditions Intermittent communication problems or erratic operation may require network speed drops to 9600 or 19200 Bauds Varying the network speed does not notice ably change the operation speed of the system Note 1 Connecting several KT 1 at a single point i...

Page 36: ...Note 4 If you must make up your own RS 232 cable with a RJ 12 connector refer to the following diagram for the RJ 12 pin out Copyright 2016 all rights reserved 36 ...

Page 37: ...e If using an external power supply reconnect the 12 VDC connection The KT 1 can be installed in enclosure KT 1 CAB along with compatible power sup ply model KT PS4085 When used in this configuration the KT 1 is also provided with 4h of standby power For KT PS4085 use Plug in adapter PTC1640UG and bat tery rated 12V 7Ah Only apply power to the unit once all connections have been completed tested a...

Page 38: ... the One Button which are dependant upon how long a finger is placed over the button 1 Status LED Hold for 3 seconds to turn on the status LED for 10 minutes Hold it another 3 seconds to turn it off 2 Entrapass Enrollment Hold for 6 seconds to trigger enrollment to EntraPass for 10 minutes and activate the status LED Hold another 6 seconds to turn off enrollment and status LED 3 Fifth Input It can...

Page 39: ... 1 The reset but ton is on the bottom right side and is accompanied by a legend detailing the reset options KT 1 with cover removed L and enlargement of reset button R There are four reset options Soft Reset Hard Reset Forced IP Reset and Factory Default DHCP mode The reset options are illustrated in the chart which follows Copyright 2016 allrights reserved 39 ...

Page 40: ...buffer is maintained if still valid Previous IP address is kept if defined The flashing beat of the vital LED follows what it was before reset occurs either Off Line communication state fast beat or normal communication 1 beat sec Global or 3 beats sec Corporate Controller generates the appropriate message a Power ON Soft Reset b Manual Pushbutton Soft Reset c Operator Soft Reset Hard Reset All co...

Page 41: ... received on any effective comm port ETH RS 485 which will configure Controller Master Mode Power LED Status Indicator There are two power LED status indicators one green and one yellow The colors indicate when the primary power supply is present The specific LED which illu minates is dependent upon the power source WARNING DO NOT LOOK DIRECTLY AT LED WITH UNSHIELDED EYES OR DAMAGE TO RETINA MAY O...

Page 42: ...ot dispose of the batteries or PCB in a fire Do not dis assemble the batteries Do not apply pressure to deform the batteries Ensure that the above precautions are strictly observed by related departments including but not limited to production sales and outside contractors CAUTION Risk of Fire Explosion And Burns Do Not Recharge Disassemble Heat Above 100 C Or Incinerate Configuring the KT 1 with ...

Page 43: ...er a Port UDP only 7 Click on Save configuration to KT 1 8 When you go to the site with the configured KT 1 you will have to enter the same details into the EntraPass workstation Configuring the KT 1 with the KT Finder The KT Finder is an application used to configure the KT 1 over the local area net work LAN or the wide area network WAN It doesn t require any installation The KT Finder applicatio...

Page 44: ...r LED Status Indicator table for details 3 Start the KT Finder Note If you try to run the KT Finder while running EntraPass you will get an error message similar to this 4 Select KT 1 from the Device menu 5 Enter the MAC address of the KT 1 then click on Connect 6 When the KT 1 is found the configuration page displays Copyright 2016 all rights reserved 44 ...

Page 45: ... information 8 Select a Protocol UDP or TCP 9 Change the Port number if required not applicable in TCP Note The port number should only be changed when you have more than one KT 1 at the same remote site 10 Click OK 11 Repeat the procedure for each KT 1 at this site Copyright 2016 allrights reserved 45 ...

Page 46: ...ctor board Compatible with KT 1 CAB M or P KT 1 CVR Black replacement cover for KT 1 including back box KT 1 CAB M Metal enclosure only for KT 1 PCB Miscellaneous Items USB 485 USB 485 interface USB cable 0 9 m 3 ft and USB drivers on CD ROM VC 485 VC 485 interface RS 232 cable 3 m 10 ft with RJ 12 connectors 740 1012 DB25F to RJ 12 adaptor 740 1022 DB9F to RJ 12 adaptor and 740 1033 DB25M to RJ 1...

Page 47: ...nd 34bits XSF 39bits have been tested and found to comply Kantech XSF 39bits have been tested and found to comply Use of a ULrecognized tamper switch on every housing cabinet for the KT 1 One Door Controller Do not use the SmartLink option Do not use a 230VAC transformer not ULlisted Use only ULlisted cables Use only ULlisted adaptors Use only a ULlisted power supply such as Kantech part number KT...

Page 48: ...figuration The CentralSupervisory Equipment shallemploy supply line transient protection complying with the Standard for Transient Voltage Surge Suppressors UL1449 with a maximum marked rating of 330V The CentralSupervisory Equipment shallemploy signalline Transient protection complying with the Standard for Protectors for Data Communications and Fire Alarm Circuits UL497B with a max imum marked r...

Page 49: ...ond the fault the number of separate signals on a single channelshallbe limited to 1000 Minimum 4 hours of stand by power provided by a standby rechargeable battery rated 12V 7Ah Loss of AC signalis transmitted immediately to the centralstation Required use of Reader s LED flashing as acknowledgement signalindicator Use EntraPass and under Definition Alarm System Door enable the option Supervised ...

Page 50: ......

Reviews: