6. Data Output
26
6.5.2 Transmission of Stored Data (data stored in memory)
Display
Procedure
<To set humidity related data output>
Enter
“F ”
. After the command is received, “AF” will be returned
and humidity related data such as DT, WB, AH, and HR will be
added in the subsequent data output.
Display
Procedure
<To release humidity related data output >
Enter
“G ”
. After the command is received, “AG” will be returned
and humidity related data such as DT, WB, AH and HR will not be
added in the subsequent data output.
Display
Procedure
<To output stored page number >
Enter
“P ”
. After the command is received, “AP” will be returned
and the stored page number will be output.
Display
Procedure
<To output stored data >
Enter
“T
****
”
.
(Enter the page number of the stored data you
want to output in 4 digit number.) After the command is received,
“AT” will be returned.
The raw data stored in the specified page will be output.
*Any calculation data such as min, average and max value, will not
be output. (As for %OA, only the average value in a page will be
output.
*The measurement unit in the output data depends on the current
measurement unit setting.
What will be output?
- CALCULATION Mode (Before sending [F] command)
Data No.; CO; CO
2
; Temperature; Humidity
- CALCULATION Mode (After sending [F] command)
Data No.; CO; CO
2
; Temperature; Humidity; DT; WB; AH; HR
- Percent Outdoor Air (%OA) Mode
Data No.; %OA; R_A; S_A; O_A
Display
Procedure
<To output measurement condition>
Enter
“M
****
”
. (Enter the page number of the measurement condition
to be output in 4 digit number.) After the command is received, “AM” will be
returned and the measurement condition of the specified page will be output.
What will be output?
1.
Measurement Mode
000: CALCULATION Mode
001: %OA Mode
2.
Sampling Time
3.
Number of Data
4.
Calculation Mode
CALCULATION Mode-- AVG: average/ INS: Instant
%OA Mode -- TMP: Temperature/ CO2: CO
2
5.
Configured Atmosphere Pressure
Display
Procedure
<To output measurement condition of all pages>
Enter
“B ”
. After the command is received, “AB” will be returned and the
measurement condition of all pages will be output. (Output items are the same
as when to output measurement condition.)
Display
Procedure
<Error Message>
If the page number is entered incorrectly,
“ED”
will be returned.
AP
P0011
AT
2004/05/19;13:32:26
001;
0.9;
576;
23.4;
63.4
002;
0.8;
556;
23.4;
63.3
003;
0.8;
534;
23.5;
63.2
004;
0.9;
540;
23.5;
63.2
005;
0.9;
561;
23.4;
63.3
3.
5.
AM
CTH;000;001;003;AVG;1013
1
.
2.
4.
AB
CTH;000;001;003;AVG;1013
CTH;001;001;005;TMP;1013
ED
* YY/MM/DD format is configured
as the date format in the output.
Therefore, the date setting on the
instrument will not be reflected in
the output.
AF
AG