TECHNICAL DESCRIPTION
MULTICAL® 62
Ka st up A/“ •
Technical
Des iptio •
5512-1036-GB_D1
•
.2016
6
1
General Description
MULTICAL® 62 is a cold water meter (0.
…
C) and hot water meter (0.1
C…
C), consisting of the
flow sensor part, ULTRAFLOW® 24, and the calculator MULTICAL® 62 (which is also identical with
MULTICAL® 602)
MULTICAL® 62 is a static water meter based on the ultrasonic principle. The water meter has been
developed on the basis of our experiences, since 1991, with the development and production of static
ultrasonic meters. MULTICAL® 62 is an accurate and reliable meter for either battery or mains operation
(optional).
Following applies for MULTICAL® 62:
According to OIML R49 MULTICAL® 62 can be described
as a o plete ate ete
. In
practice, this means that the flow part and the calculator must not be separated.
If the flow part and the calculator have been separated, and the seals have therefore been
broken, the meter is no longer valid for billing purposes. Furthermore, the factory guarantee
no longer applies.
Possible reading options are: Operating hour counter, current flow, max and min. flow,
information code, customer number and segment test etc.
–
depending on configuration.
All data are saved daily in an EEPROM for 460 days. Moreover, monthly data for the last three
years, yearly data for the last 15 years and the last 1,392 hours are saved.
MULTICAL® 62 can be fitted with plug-in modules in both calculator top (top modules) and in
connecting base (base modules). Thus, the meter can be adapted to many different
applications and data readings.
In addition to
the ate ete s o data, MULTICAL® has t o e t a pulse i puts, VA a d
VB, for collection and remote accumulation of pulses from e.g. water and electricity meters.
The pulse inputs are included in the base modules. Pulse inputs, VA and VB, function
independently of the other in- and outputs.
Flow part
MULTICAL® 62
Calculator MULTICAL® 62
(identical with MULTICAL® 602