TECHNICAL DESCRIPTION
MULTICAL® 62
Ka st up A/“ •
Technical
Des iptio •
5512-1036-GB_D1
•
.2016
24
4.6
Set-up via the front keys
Via the main key
and the sub-key
on MULTICAL® 62, a number of settings can be selected.
4.6.1
Activate the setup-menu
The setup-menu is activated in the following way:
1)
Select the display reading that you wish to change
2)
Remove the calculator from the base
3)
Wait until the display goes blank (up to 2.5 minutes). Meanwhile do not touch the front keys
4)
While replacing the calculator on the base, press and hold the main key for approx. 8 seconds
5)
The setup-menu is now active
Having activated the setup-menu, the register that you wish to change is now displayed with the
rightmost digit flashing (in the below for example
the Date
has been selected):
If the selected display register is not supported,
a f o t ke sele tio setup ,
the meter will show
the normal display, without activating the setup-menu.
4.6.2
Setup of a display register
When the setup-menu is activated, the actual value in the register selected will be displayed (in the
below example the date 2011.07.14)
The value of the flashing digit can be increased by pressing the sub-key:
When pressing the main key, the next digit to the left will be flashing: