10.5
Supply module 230 VAC
This PCB module is galvanically separated from the mains supply and is suited for direct 230 V mains
installation. The module contains a double chamber safety transformer that meets the demands for double
insulation, when the calculator top has been mounted. The power consumption is less than 1.5 VA/0.7 W.
National electricity installation requirements must be met. The 230 VAC module must be connected/dis-
connected by the utility staff, whereas, the fixed 230 V installation for the switch cabinet must only be
made by an authorised electrician.
10.6
Supply module 24 VAC
This PCB module is galvanically separated from the 24 VAC mains supply and is suited for both industrial
installations with joint 24 VAC supply and individual installations supplied from a separate 230/24 V safety
transformer in the switch cabinet. The module contains a double chamber safety transformer, which
meets the demands for double insulation, when the calculator top is mounted. The power consumption
(without an external 230/24 V transformer) is less than 1.5 VA/0.7 W
.
National electricity installation requirements must be met. The 24 VAC module must be connected/dis-
connected by the utility staff, whereas installation of 230/24 V in the switch cabinet must only be made