MULTICAL® 62
TECHNICAL DESCRIPTION
Ka st up A/“ •
Technical
Des iptio •
5512-1036-GB_
D •
.2016
65
Type 602-0C: 2 pulse outputs for CV
This top module has two configurable pulse outputs,
which are suitable for volume and energy pulses for heat
meters, cooling meters and combined heat/cooling
meters.
The pulse resolution follows the display (fixed in the CCC-
code).
The pulse outputs are optoinsulated and can be charged
with 30 VDC and 10 mA.
Normally volume (CV) is connected to 18-19, but other
combinations can be selected via the PC program
METERTOOL, also used to select pulse duration 32 or 100
ms.
11.1.2
Mounting and dismounting the top module
T
he top module is released by pressing down at the middle, to the left, of the plastic item, while
pushing the top module to the left.
Figure 21