Lock Responses
The tables below summarize how the red and green LEDs are flashed in di vid u al ly, si mul ta neous ly, or in com bi na tion
to indicate various conditions. Each LED flash is ac com pa nied by a beep for audio re in force ment.
Flashes
Green LED
Red LED
Continuous
SA Key* Required at Reader
Low Power
1
Keystroke Entry
2
Input Accepted General Error
3
Lock Ready to Open Bad Attempt to Open
4
User ID Added/Deleted Manually
* The SA key is used to transfer information between the lock and the PC.
Flashes
Green / Red Sequence
Simultaneous Green-Red
Continuous
Download in Progress
1
CLR Key Depression Lock Powered
2
Device Error ** Procedure End; Re-lock or Penalty Time Expired
** Contact Customer Service for assistance.
• One simultaneous flash of the green and red LEDs ac com pa nied by a beep in di cates that the lock is powered.
• When power drops below a suf fi cient level for operation, the lock will con tin u al ly beep and flash the red LED. At this
point, the operator has 5 seconds in which to regenerate power to a sufficient level before the lock will sys tem at i cal -
ly shutdown. To regenerate power, depress the outside lever through a 67-degree open and 67-degree restore rota-
tion.
• After each accepted step of an operation, two flashes of the green LED display and two beeps sound, prompting
you to enter additional information for the next step of the operation. The User must wait for these prompts
before proceeding.
• After you have completed all the steps of an operation, two si mul ta neous flashes of the green and red LED display
and two beeps sound if the op er a tion is suc cess ful. Two red flashes display and two beeps sound if the op er a tion is
un suc cess ful and you will need to re-key the operation which caused the error.
Programmable Features
The PowerLever Door Lock has the following programmable features.
Lockout
Managerial personnel can control the entry of Access Users and Service Users by enabling and disabling available
entry. Lock entry rights can be pro grammed for specific users or all Access Users and Service Users.
Note: The Master User and Manager Users are not affected by the lockout.
Re-Lock Time
The re-lock time (i.e. the time that the lock remains open before re-locking) can be pro grammed by man a ge ri al per-
sonnel from 2 to 20 seconds, with a factory set default of 4 seconds. The lock automatically re-locks after the re-lock
time has expired. The re-lock is indicated by an audible “click”.