Getting Started
This section identifies lock setup activities and startup operations.
Open Shelved Lock Using Default Combination
The lock can be opened while in a Shelved state using the default Master User combination of all 0’s.
Note: The lock is shipped pre-set from the factory with the default Master User com bi na tion of 00000000 (User
ID=0000; PIN = 0000).
Step
Detailed Instructions
1.
Power lock.
Power the lock by depressing the outside lever.
2.
Enter Master User default
Enter the Master User default combination of all 0’s. The lock will beep and
combination of all 0’s.
flash the green LED on each keystroke entered. (If the Clear key is pressed
during data entry, the lock re sponds with one alternate beep/flash of the
green and red LED, and all digits of the com bi na tion must be re-entered.)
The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock re-
sponds with three beeps/flashes of the red LED.
Caution: When opening the lock, do not depress the outside lever until the lock responds with three
beeps/flashes of the green LED to indicate available entry.
3.
Open lock.
Before re-lock time expires, depress the outside lever to open the lock. At
the end of the re-lock interval the lock will respond with two simultaneous
beep/flashes of the red and green LEDs.
Note: If a lock has been Activated and then Shelved, the lock returns to a state where it can be opened with the
default Master User com bi na tion of all 0’s. The length of the default combination will be the currently defined length
of the User ID + the currently defined length of the PIN.
Lock Setup Activities
The following provides a brief list of the activities that are to be per formed by the Master User and, op tion al ly,
Manager Users to configure the lock for lock op er a tions. The in struc tions for performing these activities are located
on the in di cat ed pages.
Master User
1. Determine Model Type* (Optional) (page 23)
* This operation can also be performed by Manager Users when ac ti vat ed.
2. Define number of Key Access Users and Keypad User PIN Field Length (page 14)
3. Activate the Lock (page 14)
4. Activate a Manager User (Optional) (page 15)
Master User / Manager User
5. Set Lock Time and Date (page 16)
6. Set Re-Lock, Wrong Try Limit, and Penalty Times (page 16)
Lock Startup Operations
Note: Before any startup operations can be performed, the activities listed in the previous “Lock Setup Ac tiv i ties”
section must be completed.
The following provides a brief list of the operations that should be per formed to enable full operation ca pa bil i ties of
the lock. The instructions for performing these activities are located on the indicated pages.
Summary of Contents for PowerLever 455 Series
Page 1: ...PowerLever 455x Operating Instructions...
Page 37: ...37 Notes...
Page 38: ...38 Notes...
Page 39: ...39 Notes...