Retrieve Audit Records
On the Model 455x PowerLever Lock, audit records may be retrieved using either an SA Key or a Palm Organizer.
Each audit transaction includes a date and time stamp. Only the most recent 1,022 audit records can be placed on
the SA Key. Down loads of audit records numbering greater than 1,022 will require the Palm Organizer. If you have
pur chased the PowerLever Door Lock PC soft ware for re port ing ca pa bil i ties, the audit trail data stored in the lock can
be read from the lock and taken to the PC for re port ing.
To retrieve audit records, complete the following steps:
Note:The retrieve audit records operation requires an SA key that has been ini tial ized at the PC or a Palm organizer.
Refer to Ap pen dix B of the PowerLever Door Lock Soft ware Ref er ence Manual for a flow chart of the Retrieve Audit
Records process that combines activity at the lock and the PC.
Audit Record Retrieval Via SA Key
Step
Detailed Instructions
1.
Power lock.
Power the lock by depressing the outside lever.
2.
Enter combination.
Enter the combination. The lock will beep/flash the green LED on each key-
stroke entered. If the Clear key is pressed during data entry, the lock
responds with one beep/flash of the green LED followed by the red LED, and
all digits of the com bi na tion must be re-entered. The lock responds with
three beeps/flashes of the green LED to indicate available entry. If the com -
bi na tion is not valid, the lock re sponds with three beeps/flashes of the red
LED.
3.
Press then 00.
Before re-lock time expires, press (Enter key) followed by the 0 key and
then the 0 key again. The lock responds with one beep/flash of the green
LED every second until the SA key is inserted into the lock key reader.
4.
Insert SA Key into Key reader.
Insert the SA Key into the lock key reader. The lock al ter nate ly beeps/flashes
red and green LEDs while audit down load ing is in progress.
Note: If at any time during the procedure the lock power drops below a sufficient level for operation, the lock will
continually beep and flash the red LED, prompting the user to depress the outside lever to provide additional
power within five seconds.
5.
Ensure lock remains powered
Ensure that the lock remains powered and the SA Key remains in the
and SA Key remains in reader
reader until the lock has com plet ed down load ing the reporting data. Upon
until complete.
com ple tion, the lock responds with two simultaneous beeps/flashes of the
green and red LEDs.
The lock audit trail has now been downloaded to the SA Key.
Audit Record Retrieval Via Palm Organizer
Step
Detailed Instructions
1.
Connect Palm Organizer
Connect the Palm Interface Module to the lock using the interface cable.
to lock.
2.
Power lock.
Power the lock by depressing the outside lever.
3.
Enter combination.
Enter the combination. The lock will beep/flash the green LED on each key-
stroke entered. If the Clear key is pressed during data entry, the lock
responds with one beep/flash of the green LED followed by the red LED, and
all digits of the com bi na tion must be re-entered. The lock responds with
three beeps/flashes of the green LED to indicate available entry. If the com -
bi na tion is not valid, the lock re sponds with three beeps/flashes of the red
LED.