JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS23x, 34x, 43x
141
8.2.64
Turntable_Mode
Description: In turntable mode, the motor controls the revolution of a turntable that has the number
of positions specified in register 127, Turntable_Size. This means the same position will
be reached after rotating this number of steps in either direction.
This register selects one of three modes that define how the motor should move to a
new position when the P_SOLL register is changed.
If the value of this register is zero, the motor will not operate in turntable mode.
In mode 1, the motor will always move to a new position by turning in a positive direc-
tion. So to move one step backwards, it must instead move Turntable_Size-1 steps
forward.
In mode 2, the motor will always move to a new position by turning in a negative
direction.
In mode 3, the motor will move in the direction that takes the smallest number of
steps to reach the new position.
Note that the motor will not move at all if the new position in register P_SOLL is either
negative or larger than the value of register 127, Turntable_Size.
8.2.65
Turntable_Size
Description: If turntable mode is selected in register 126, the number of steps needed for a full revo-
lution of the turntable is set in this register. Note that the register P_SOLL must always
have a value between zero and the value in this register minus one. Negative values are
not allowed for P_SOLL or Turntable_Size.
8.2.66
NL_Mask
Description: Selects which one of the eight IO pins to use for the dedicated function of Negative Po-
sition Limit.
Exactly one bit must be set, and the IO pin must be configured in register 125 as an
input.
Example:
If input 7 is to be used for the Negative Input Limit, write 26 = 64 to this
register.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
126
TURNTABLE_
MODE
16bit
R/W
-
0
Special
Turn Table -Mode
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
127
TURNTABLE_
SIZE
32bit
R/W
-
0
Steps
Turn Table - Size
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
129
NL_MASK
16bit
R/W
-
0
IO Mask
Dedicated Inputs
Negative Limit Input
Summary of Contents for MIS23 Series
Page 6: ...6 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 29: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 27 ...
Page 56: ...54 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 116: ...114 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 188: ...186 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 260: ...258 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 335: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 333 ...
Page 341: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 339 ...