154
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS23x, 34x, 43x
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
112-
115
SAMPLE1-4
32bit
R/W
-
0
-
N/A
116
REC_CNT
32bit
R/W
-
0
-
N/A
117
S_TIME
32bit
R/W
-
1
ms
N/A
118
S_CONTROL
32bit
R/W
-
0
-
NA
119
BUF_SIZE
32bit
R
-
-
-
N/A
120
INDEX_OFFSET
32bit
R
0-1599
-
Steps
Tests-
121
ModbusSetup
32bit
R/W
-
-
-
-
Bit explanation (* = default):
D0
: 0=Disabled *, 1=Enabled,
When set to non-zero, selects to start the switch away from the MacTalk
protocol and start the Modbus protocol.
D1
: 0=Modbus RTU*
1=Modbus ASCII
This field is not current used. The motor always uses the binary Modbus RTU
format.
D3-D2
: 0=No parity, 1=Odd
parity, 2=Even parity*
Select the parity bit value. Select the same format as the Modbus client PLC,
HMI or PC uses. (3:2 is read as ‘bits 3 through 2’)
D4
: 0=7 data bits,1=8 data bits*
Number of data bits in a byte. Modbus RTU always uses 8 bits per byte.
D5
: 0=1 stop bit*, 1=2 stop bits
Select the number of stop bits. Select the same format as the Modbus client
PLC, HMI or PC uses
D31-D6
Unused - reserved for future purposes
122
HOME_BITS
32bit
R/W
-
0
Special
Advanced-Zero
Search
123
Reserved
32bit
R/W
-
-
-
N/A
124
SETUP_BITS
32bit
R/W
-
0
Special
Don't start program
after power up.
Invert motor direc-
tion.
External Encoder
Enable DSP 402
Support
Auto encoder
synchronize
125
IOSETUP
32bit
R/W
-
0
Special
Inputs/Outputs
126
TURNTABLE_
MODE
32bit
R/W
-
0
Special
Turn Table -Mode
127
TURNTABLE_
SIZE
32bit
R/W
-
0
Steps
Turn Table - Size
129
NL_MASK
32bit
R/W
-
0
IO Mask
Dedicated Inputs
Negative Limit In-
put
130
PL_MASK
32bit
R/W
-
0
IO Mask
Dedicated Inputs -
Positive Limit Input
131
Reserved
32bit
R/W
-
0
132
HOME_MASK
32bit
R/W
-
0
IO Mask
Dedicated inputs.
Home Input
133
-134
Reserved
-
-
-
-
-
135
INPUT_FILTER_
MASK
32bit
R/W
-
0
IO Mask
IOx digital input
filter enabled
136
INPUT_FILTER_
CNT
32bit
R/W
-
5
ms
Input filter time
137
INPOS_MASK
32bit
R/W
-
0
IO MASK
Dedicated Outputs
- In Position
138
ERROR_MASK
32bit
R/W
-
0
IO Mask
Dedicated Outputs
- Error
Summary of Contents for MIS23 Series
Page 6: ...6 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 29: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 27 ...
Page 56: ...54 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 116: ...114 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 188: ...186 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 260: ...258 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 335: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 333 ...