[Alarm Environment] Page
This page sets up the alarm environment.
This page can be used during access using
“admin” or “operator”.
0
Click [Advanced Settings] in the side menu, and
click [Alarm Environment].
0
Press the [OK] button to enable the new
settings.
0
If the [OK] button is pressed upon entering an
invalid value, a warning message will appear
and the entry will be denied. Press the [Cancel]
button to restore the invalid entry to the value
before the change was made. If you press the
[Cancel] button, other changed items will also be
restored to the values before the change was
made.
Settings
.
* Setting values with
R
are default values.
Mail Settings
For setting the mail environment when [Mail] is
specified as an action on the Alarm page. If [SMTP
Server], [Port Number], and [Send Mail Address]
are set, the alarm action is displayed as “Preset”.
SMTP Server
For setting the IP address or FQDN of the SMTP
server.
What is FQDN (Fully Qualified Domain Name)?
:
This is a fully qualified domain name that indicates
a notation method of describing the entire host or
domain name on the TCP/IP network without
abbreviating.
For example, if the host name is www and the
domain name is jvckenwood.co.jp, this will be
denoted as “www.jvckenwood.co.jp” in FQDN.
Japanese cannot be used in FQDN. If FQDN is
specified, set also the DNS server on the Network
page.
Port Number
Input the port number.
[Set values: 1 to
R
25 to 65535]
Send Mail Address
Specify the sender’s mail address.
POP before SMTP
To enable [POP before SMTP], select “Enable” and
set the POP server.
[Set values:
R
Disable, Enable]
9
POP Server
For setting the IP address or FQDN of the POP
server.
9
Port Number
Input the port number.
[Set values: 1 to
R
110 to 65535]
9
User Name
Enter the user name.
9
Password
Enter a password.
Alarm Output
Configure settings related to alarm output from an
alarm output cable or connector.
Duration
Set the output duration for [Manual Output].
[Set values:
R
0, 100 to 5000]
msec
Manual Output
Manually operate alarm output.
The current output status is displayed on the right
side. When [Duration] is set to “0”, pressing the
[Make] button sets the alarm to make output, and
pressing the [Break] button sets the alarm to break
output.
When [Duration] is set to other than “0”, pressing
the [Make] button sets the alarm to make output
only for the output duration time, and then changes
it to break output.
When [Duration] is set to other than “0”, pressing
the [Break] button sets the alarm to break output
only for the output duration time, and then changes
it to make output.
[Set values: Make,
R
Break]
42
[Advanced Settings] Page - [Alarm Environment] Page