1-54 (No. 52152)
CHROMA ADJUSTMENTS (PAL)
Measuring Instruments
Signal generator (Color bar signal)
Oscilloscope
Card (Slot)
NTSC/PAL Video Input Card (Slot 2)
Test Points
TP-47B [CRT SOCKET PWB]
TP-GND [CRT SOCKET PWB]
Adjustment Points
S*03 (Chroma) [Service Menu]
Notes:
•
Ensure that the output waveforms from the NTSC/PAL
Video Input Cards are normal before proceeding to the
following adjustments.
•
Perform the following adjustments after completing
the 1080/60i signal Chroma/Phase Adjustments.
•
Set the CHROMA and PHASE data in the Setup Menu
to “00”.
•
The SR value (see the description of the Component
Signal Chroma/Phase Adjustments) becomes the
reference value for the following adjustments. When
this data is changed, it is required to re-adjust the data
of all of the adjustment signals (Component, NTSC and
PAL).
When re-adjusting the 1080/60i signal, use the SI. (For
the adjustment of the 1080/60i signal, use the
Component/RGB Input Card.)
(1) Apply the PAL 75% color bar signal to INPUT C (Terminal
VIDEO1 on the NTSC/PAL Video Input Card).
(2) Set the CHROMA and PHASE potentiometers on the front
panel to the center click positions.
(3) Connect the oscilloscope across TP-47B and TP-GND.
(4) Adjust
SC03
in the Service Menu to set the level difference
between waveforms 1 and 4 in the figure on the right to
0
V ± 2 V
.
(5) Apply the PAL 75% color bar signal to INPUT D (Terminal
Y/C on the NTSC/PAL Video Input Card) and perform the
adjustments in steps 2 to 4 above. See Table 7 for the
adjustment data.
Table 7
Adjustment
Adjustment Data
Signal
Chroma
PAL (VIDEO)
SC03
PAL (Y/C)
SD03
4
3
2
1