(No. 52152) 1-3
1.1 SAFETY PRECAUTIONS
(1) The design of this product contains special hardware,
many circuits and components specially for safety
purposes. For continued protection, no changes should
be made to the original design unless authorized in writing
by the manufacturer. Replacement parts must be identical
to those used in the original circuits. Service should be
performed by qualified personnel only.
(2) Alterations of the design or circuitry of the products should
not be made. Any design alterations or additions will void
the manufacturer's warranty and will further relieve the
manufacturer of responsibility for personal injury or
property damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
s p e c i a l s a f e t y - r e l a t e d c h a r a c t e r i s t i c s . T h e s e
characteristics are often not evident from visual inspection
nor can the protection afforded by them necessarily be
obtained by using replacement components rated for
higher voltage, wattage, etc. Replacement parts which
have these special safety characteristics are identified in
the parts list of Service manual.
Electrical components
having such features are identified by shading on
the schematics and by ( ) on the parts list in Service
manual.
The use of a substitute replacement which does
not have the same safety characteristics as the
recommended replacement part shown in the parts list of
Service manual may cause shock, fire, or other hazards.
(4)
Use isolation transformer when hot chassis.
The chassis and any sub-chassis contained in some
products are connected to one side of the AC power line.
An isolation transformer of adequate capacity should be
inserted between the product and the AC power supply
point while performing any service on some products when
the HOT chassis is exposed.
(5)
Don't short between the LIVE side ground and
ISOLATED (NEUTRAL) side ground or EARTH side
ground when repairing.
Some model's power circuit is partly different in the GND.
The difference of the GND is shown by the LIVE : ( ) side
GND, the ISOLATED(NEUTRAL) : ( ) side GND and EARTH
: (
) side GND. Don't short between the LIVE side GND
and ISOLATED(NEUTRAL) side GND or EARTH side GND
a n d n e v e r m e a s u r e t h e L I V E s i d e G N D a n d
ISOLATED(NEUTRAL) side GND or EARTH side GND at the
same time with a measuring apparatus (oscilloscope etc.).
If above note will not be kept, a fuse or any parts will be
broken.
(6) If any repair has been made to the chassis, it is
recommended that the B1 setting should be checked or
adjusted (See ADJUSTMENT OF B1 POWER SUPPLY).
(7) The high voltage applied to the picture tube must conform
with that specified in Service manual. Excessive high
voltage can cause an increase in X-Ray emission, arcing
and possible component damage, therefore operation
under excessive high voltage conditions should be kept
to a minimum, or should be prevented. If severe arcing
occurs, remove the AC power immediately and determine
the cause by visual inspection (incorrect installation,
cracked or melted high voltage harness, poor soldering,
etc.). To maintain the proper minimum level of soft X-Ray
emission, components in the high voltage circuitry
including the picture tube must be the exact replacements
or alternatives approved by the manufacturer of the
complete product.
(8) Do not check high voltage by drawing an arc. Use a high
voltage meter or a high voltage probe with a VTVM.
Discharge the picture tube before attempting meter
connection, by connecting a clip lead to the ground frame
and connecting the other end of the lead through a 10k
Ω
2W resistor to the anode button.
(9) When service is required, observe the original lead dress.
Extra precaution should be given to assure correct lead
dress in the high voltage circuit area. Where a short circuit
has occurred, those components that indicate evidence
of overheating should be replaced. Always use the
manufacturer's replacement components.
(10)
Isolation Check
(Safety for Electrical Shock Hazard)
After re-assembling the product, always perform an
isolation check on the exposed metal parts of the cabinet
(antenna terminals, video/audio input and output terminals,
Control knobs, metal cabinet, screwheads, earphone jack,
control shafts, etc.) to be sure the product is safe to operate
without danger of electrical shock.
a)
Dielectric Strength Test
The isolation between the AC primary circuit and all metal
parts exposed to the user, particularly any exposed metal
part having a return path to the chassis should withstand
a voltage of 1100V AC (r.m.s.) for a period of one second.
(. . . . Withstand a voltage of 1100V AC (r.m.s.) to an
appliance rated up to 120V, and 3000V AC (r.m.s.) to an
appliance rated 200V or more, for a period of one second.)
This method of test requires a test equipment not generally
found in the service trade.
b)
Leakage Current Check
Plug the AC line cord directly into the AC outlet (do not
use a line isolation transformer during this check.). Using
a “Leakage Current Tester”, measure the leakage current
from each exposed metal part of the cabinet, particularly
any exposed metal part having a return path to the chassis,
to a known good earth ground (water pipe, etc.). Any
leakage current must not exceed 0.5mA AC (r.m.s.).
However, in tropical area, this must not exceed 0.2mA AC
(r.m.s.).
•
Alternate Check Method
Plug the AC line cord directly into the AC outlet (do not
use a line isolation transformer during this check.). Use
an AC voltmeter having 1000 ohms per volt or more
sensitivity in the following manner. Connect a 1500
Ω
10W
resistor paralleled by a 0.15µF AC-type capacitor
between an exposed metal part and a known good earth
ground (water pipe, etc.). Measure the AC voltage across
the resistor with the AC voltmeter. Move the resistor
connection to each exposed metal part, particularly any
exposed metal part having a return path to the chassis,
and measure the AC voltage across the resistor. Now,
reverse the plug in the AC outlet and repeat each
measurement. Any voltage measured must not exceed
0.75V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.).
However, in tropical area, this must not exceed 0.3V AC
(r.m.s.). This corresponds to 0.2mA AC (r.m.s.).
(11)
High voltage hold down circuit check.
After repair of the high voltage hold down circuit, this circuit
shall be checked to operate correctly.
See
“X-RAY PROTECTOR ADJUSTMENT/CHECK”
on
page 1-44.
GOOD
EARTH
GROUND
0.15 µF AC-TYPE
AC VOLTMETER
(HAVING 1000
Ω
/V,
OR MORE SENSITIVITY)
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
1500
Ω
10W
A V
This mark shows a fast
POWER CORD
REPLACEMENT WARNING
Connecting the white line side of
power cord to “WHT” character side.
operating fuse, the
letters indicated below
show the rating.
PWB
WHT
PW
White line side