Table 19: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device
Seismic
Temperature
Relative Humidity
Altitude
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured
in the temperature range
32° F (0° C) through 104°
F (40° C)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8208
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured
in the temperature range
32° F (0° C) through 104°
F (40° C)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8216
Complies with Zone
4 earthquake
requirements as per
GR-63.
Normal operation is ensured
in the temperature range
32° F (0° C) through 104°
F (40° C)
Nonoperating storage
temperature in shipping
container: – 40° F (–40° C)
to 158° F (70° C)
Normal operation ensured
in the relative humidity
range 5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9204
Complies with Zone
4 earthquake
requirements as per
GR-63.
Normal operation is ensured
in the temperature range
32° F (0° C) through 104°
F (40° C)
Nonoperating storage
temperature in shipping
container: – 40° F (–40° C)
to 158° F (70° C)
Normal operation ensured
in the relative humidity
range 5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9208
Complies with Zone
4 earthquake
requirements as per
GR-63.
Normal operation is ensured
in the temperature range
32° F (0° C) through 104°
F (40° C)
Nonoperating storage
temperature in shipping
container: – 40° F (–40° C)
through 158° F (70° C)
Normal operation ensured
in the relative humidity
range 5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9214
53
Summary of Contents for XRE200 -
Page 1: ...XRE200 External Routing Engine Hardware Guide Published 2020 12 15...
Page 135: ...135...
Page 142: ...142...
Page 155: ...Jewelry Removal Warning 155...
Page 158: ...Operating Temperature Warning 158...
Page 168: ...DC Power Disconnection Warning 168...
Page 172: ...DC Power Wiring Sequence Warning 172...