– 96 –
Error
code
Display
Description of error
Display message
How to
recover
Place of
recovery
E030
Needle bar position missing
error
Needle bar is not in the
predetermined position.
Turn hand
pulley to
bring needle
bar to its
predetermined
position.
Data
input
screen
E031
Air pressure drop
Air pressure is dropped.
Possible
to re-start
after reset.
Data
input
screen
E032
File interchanging error
File cannot be read.
Possible
to re-start
after reset.
Data
input
screen
E040
Sewing area over
Possible
to re-start
after reset.
Sewing
screen
E043
Enlarging error
Sewing pitch exceeds Max.
pitch.
Possible
to re-start
after reset.
Data
input
screen
E045
Pattern data error
Possible
to re-start
after reset.
Data
input
screen
E050
Stop switch
When stop switch is pressed
during machine running.
Possible
to re-start
after reset.
Step
screen
E052
Thread breakage detection
error
When thread breakage is
detected.
Possible
to re-start
after reset.
Step
screen
E099
Stacking full
This error occurs when the
allowable number of pieces of
products to be stacked on the
stacker is exceeded.
Possible
to re-start
after reset.
Sewing
screen
E204
USB connection error
With the number of times
of sewing has reached 10
or more, with a USB device
connected to the sewing
machine
Possible
to re-start
after reset.
Sewing
screen