Troubleshooting
Operating instructions
68
Fault message on
the PLC display
Possible cause
Troubleshooting
Volume ratio
incorrect
The ratio of Anolyte to
Catholyte by volume does
not match the production
which has been set.
The reactor is calcified or
faulty.
Further production is not possible.
Start a manual descaling cycle;
see Chapter 10.8, on page 58.
Acknowledge the fault message;
see Chapter 10.9 “Acknowledging
fault messages” on page 58,.
Resume production; see
Chapter 10.3 “Switching on the
system”, page 52.
"Gauge" the volume ratio; see
Chapter 9.3 on page 47.
If the volume ratio still does not
match after several attempts
under constant process conditions
and after cleaning, please inform
GF JRG customer service.