36
Connect the output line (2) ø 6 mm from the
Calzid-Ex tank (1) to the connection (4) on
the process cabinet (3) and tighten.
Remove the cover (2) from the Salisol tank
(1).
Connect the hose ø 8 mm to the connection
(7) on the process cabinet (6) and tighten.
Connect the other end of the hose to the
water connection (3) on the Salisol tank (1).
Immerse the output hose ø 6 mm with filter
into the pipe (4) of the Salisol tank (1) until
the filter reaches the bottom of the tank.
Connect the output hose ø 6 mm to the
connection (5) on the process cabinet (6)
and tighten.
Re-attach the cover (2) of the Salisol tank
(1).
An optional overflow protection hose can be
installed on the Salisol tank. To do this, lay
a ø 12 mm hose connecting the connecting
piece (at the side of and outside of the tank)
and the waste water drain.
Thus, any surplus water will be discharged
in the event of a malfunction, e.g. of the
filling level sensor of the Salisol tank.