Operating instructions
Specifications
17
Designation
Values
Dimensions (W x H x D)
1,472 mm x 1,750 mm x 574 mm
Mounting surface area on wall (W x H)
1,800 mm x 2,000 mm
Unit weight (standard)
With empty tank
90 kg
With full tank
235 kg
Certification
CE approved
Approval of the disinfectant
German Drinking Water Ordinance
Section 11
6.1
Operating fluids
Operating fluids
Designation
Values
Calzid-Ex
Descaling and cleaning fluid consisting of organically
degradable acid for regular cleaning of the process unit.
Consumption depends on the quality of the inlet water. The
higher the conductivity of the water, the more often the
process unit has to be cleaned, and the higher the
consumption of Calzid-Ex, see Chapter 10.6 "Cleaning
Tank material
PE
Level monitoring
Float switch
Height
640 mm
Diameter
420 mm
Volume
60 L
Min. and Max. marks
80 mm, 470 mm
Refill tank
25 L
Code No. [Item No.]
351 118 020 [9818.020]
High-purity
salt
as a basis for the
Salisol
Dried white high-purity fine-grained sodium chloride (NaCl >
99.8 %). Depending on drinking water quality, the quantity
required is 0.5 — 2 g / L Anolyte / Anolyte neutral.
Grain size
0.1 – 0.9 mm
Average grain size
0.4 – 0.7 mm
Refill bag
25 kg
Code No. [Item No.]
351 118 010 [9818.010]
Summary of Contents for 9800.002