3.4 BASIC OPERATIONS
316
3
y
y
y
3.4.4 Tune
There are automatic tuning mode and manual tuning mode. In the automatic tuning mode, transmission and
receiving frequencies are tuned and adjusted automatically. In the manual tuning mode, tuning is carried out
using the dial on the operation panel. The currently selected mode is indicated on the tune mode button
(software button
ԣ
located at the bottom left corner of the radar display described in Section 2.3.2).
Using the automatic tuning mode
Procedure
1 Move the cursor to the Tune mode button (software button
ԣ
located at
the bottom left corner of the radar display described in Section 2.3.2)
and press the [ENT] key.
Automatic tuning mode is activated, and AUTO is displayed on the Tune mode button.
The equipment carries out tuning automatically. Tuning is adjusted when transmission
starts, the observation range is changed, or when the pulse width is changed. Tuning
takes only a few seconds.
Using the manual tuning mode
Procedure
1 Move the cursor to the Tune mode button (software button
ԣ
located at
the bottom left corner of the radar display described in Section 2.3.2),
press the [ENT] key, and set the mode to the manual tuning mode.
Automatic tuning mode is cancelled, and MAN is displayed on the Tune mode button.
2
Turn the [MULTI] dial to set the dial mode to (Tune) .
The multi-dial mode button (
ԥ
located at the bottom left corner of the radar display
described in Section 2.3.2) shows (Tune) .
3
Turn the [MULTI] dial to adjust tuning.
Turn the dial until the tuning state gauge (
Ԡ
located at the top left corner of the radar
display described in Section 2.3.1) reaches maximum.
Always use the automatic tuning mode.
Use the manual tuning mode only when the automatic
tuning mode does not provide the best tuning state due
to deterioration of magnetron for example.
Caution
Summary of Contents for JMA-5212-4
Page 2: ......
Page 18: ... xii NKE 2103 6 6HS Scanner Unit NKE 2254 7 9 6HS Scanner Unit Warning Label Warning Label ...
Page 19: ... xiii ...
Page 38: ... xxxii ...
Page 45: ...1 4 EXTERIOR DRAWINGS 1 6 1 y Fig 1 1 Exterior Drawing of Scanner Unit Type NKE 2103 4 ...
Page 46: ...1 7 Fig 1 2 Exterior Drawing of Scanner Unit Type NKE 2103 6 ...
Page 47: ...1 4 EXTERIOR DRAWINGS 1 8 1 y Fig 1 3 Exterior Drawing of Scanner Unit Type NKE 2254 7 ...
Page 48: ...1 9 Fig 1 4 Exterior Drawing of Scanner Unit Type NKE 2254 9 ...
Page 49: ...1 4 EXTERIOR DRAWINGS 1 10 1 y Fig 1 5 Exterior Drawing of Monitor Unit Type NWZ 164 ...
Page 50: ...1 11 Fig 1 6 Exterior Drawing of Processor Unit Type NDC 1460 ...
Page 51: ...1 4 EXTERIOR DRAWINGS 1 12 1 y Fig 1 7 Exterior Drawing of Keyboard Unit Type NCE 7699A ...
Page 52: ...1 13 Fig 1 8 Exterior Drawing of NSK Unit Type NCT 4106A ...
Page 56: ...1 17 ...
Page 58: ...2 1 2 1 EXAMPLE OF DISPLAY ...
Page 78: ...2 21 ...
Page 234: ...3 155 ...
Page 316: ...5 75 ...
Page 332: ...6 15 ...
Page 358: ...7 25 Exit 1 Press RADAR MENU key The Main Menu will reappear ...
Page 434: ...8 39 ...
Page 452: ...10 5 ...
Page 477: ...Figure 8 NKE 2254 Interconnection Diagram of Scanner Unit ...
Page 493: ......